{"id":125,"date":"2026-04-10T02:53:09","date_gmt":"2026-04-10T02:53:09","guid":{"rendered":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/chapter\/ch047-xhtml\/"},"modified":"2026-05-11T22:32:45","modified_gmt":"2026-05-11T22:32:45","slug":"6-3-sample-collection-and-analysis","status":"publish","type":"chapter","link":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/chapter\/6-3-sample-collection-and-analysis\/","title":{"raw":"6.3 Sample Collection and Analysis","rendered":"6.3 Sample Collection and Analysis"},"content":{"raw":"<div id=\"sample-collection-and-analysis-3\" class=\"level1\">\r\n<div data-custom-style=\"First Paragraph\">\r\n\r\nThe primary source of CFCs in groundwater is the atmosphere, so care must be taken to eliminate contact between the sample and the atmosphere. Furthermore, CFCs from the atmosphere tend to sorb onto sampling equipment\u2014especially items made of plastic\u2014and desorption can artificially elevate CFC concentrations. Non\u2011porous materials such as metal and glass are recommended over plastic materials whenever possible. A simple and effective sampling method uses a 125\u00a0mL glass bottle with a narrow mouth as shown in <a href=\"#figure-26\"><span data-custom-style=\"Hyperlink\">Figure 26<\/span><\/a>. The bottles and foil\u2011lined caps are placed inside a secondary beaker\u2014approximately 2L in volume\u2014and both the bottle, and the beaker are filled using a submersible pump with the discharge tube extending to near the bottom of the bottle as shown in <a href=\"#figure-26\"><span data-custom-style=\"Hyperlink\">Figure 26<\/span><\/a>. The sample bottle and beaker are purged with 3 to 4L of water before removing the discharge tube. The foil\u2011lined cap is installed underwater to eliminate any contact with the atmosphere.\r\n\r\n<\/div>\r\n<div id=\"figure-26\" data-custom-style=\"Body Text\">\r\n\r\n<img style=\"display: block; margin-left: auto; margin-right: auto; ;width: 5.5in; height: 4.1in;\" src=\"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-content\/uploads\/sites\/41\/2026\/04\/file28.png\" alt=\"\" \/>\r\n\r\n<\/div>\r\n<div data-custom-style=\"Block Text\">\r\n<blockquote>\r\n<div class=\"figcaption-text\">\r\n\r\n<span id=\"Xd5f6d9c57e5c976790ab1915930c9ae6e72f8c2\" class=\"anchor\"><\/span><strong>Figure 26\u00a0\u2011<\/strong>\u00a0Sampling water for CFCs. a) Narrow\u2011mouth glass bottle with foil\u2011lined cap. b) Bottles should be filled by inserting a tube to the bottom, flushing more than 3L, and then installing the cap with no headspace. c) Alternatively, a metal container can be used instead of the beaker of (b).\r\n\r\n<\/div><\/blockquote>\r\n<\/div>\r\n<div data-custom-style=\"First Paragraph\">\r\n\r\nThe purge\u2011and\u2011trap method is typically used to analyze CFCs because of their relatively high solubility in water. CFC\u2011free carrier gas\u2014typically [latex]N_{2}[\/latex] or [latex]He[\/latex]\u2014is bubbled through the water inside a sparging chamber and then through a trap that retains CFCs but not the carrier gas or oxygen. Traps are typically filled with a porous polymer and are held at about <em>\u2013 <\/em>30\u00a0\u00b0C. After sufficient stripping, the trap is warmed to release CFCs, which are then routed into a GC for analysis. Both packed and capillary columns have been used and typically CFC\u201111, CFC\u201112, and CFC\u2011113 can be analyzed in a single run. Because of the possibility of sample contamination during sampling, CFCs are often analyzed in triplicate or more.\r\n\r\n<\/div>\r\n<\/div>","rendered":"<div id=\"sample-collection-and-analysis-3\" class=\"level1\">\n<div data-custom-style=\"First Paragraph\">\n<p>The primary source of CFCs in groundwater is the atmosphere, so care must be taken to eliminate contact between the sample and the atmosphere. Furthermore, CFCs from the atmosphere tend to sorb onto sampling equipment\u2014especially items made of plastic\u2014and desorption can artificially elevate CFC concentrations. Non\u2011porous materials such as metal and glass are recommended over plastic materials whenever possible. A simple and effective sampling method uses a 125\u00a0mL glass bottle with a narrow mouth as shown in <a href=\"#figure-26\"><span data-custom-style=\"Hyperlink\">Figure 26<\/span><\/a>. The bottles and foil\u2011lined caps are placed inside a secondary beaker\u2014approximately 2L in volume\u2014and both the bottle, and the beaker are filled using a submersible pump with the discharge tube extending to near the bottom of the bottle as shown in <a href=\"#figure-26\"><span data-custom-style=\"Hyperlink\">Figure 26<\/span><\/a>. The sample bottle and beaker are purged with 3 to 4L of water before removing the discharge tube. The foil\u2011lined cap is installed underwater to eliminate any contact with the atmosphere.<\/p>\n<\/div>\n<div id=\"figure-26\" data-custom-style=\"Body Text\">\n<p><img decoding=\"async\" style=\"display: block; margin-left: auto; margin-right: auto; ;width: 5.5in; height: 4.1in;\" src=\"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-content\/uploads\/sites\/41\/2026\/04\/file28.png\" alt=\"\" \/><\/p>\n<\/div>\n<div data-custom-style=\"Block Text\">\n<blockquote>\n<div class=\"figcaption-text\">\n<p><span id=\"Xd5f6d9c57e5c976790ab1915930c9ae6e72f8c2\" class=\"anchor\"><\/span><strong>Figure 26\u00a0\u2011<\/strong>\u00a0Sampling water for CFCs. a) Narrow\u2011mouth glass bottle with foil\u2011lined cap. b) Bottles should be filled by inserting a tube to the bottom, flushing more than 3L, and then installing the cap with no headspace. c) Alternatively, a metal container can be used instead of the beaker of (b).<\/p>\n<\/div>\n<\/blockquote>\n<\/div>\n<div data-custom-style=\"First Paragraph\">\n<p>The purge\u2011and\u2011trap method is typically used to analyze CFCs because of their relatively high solubility in water. CFC\u2011free carrier gas\u2014typically [latex]N_{2}[\/latex] or [latex]He[\/latex]\u2014is bubbled through the water inside a sparging chamber and then through a trap that retains CFCs but not the carrier gas or oxygen. Traps are typically filled with a porous polymer and are held at about <em>\u2013 <\/em>30\u00a0\u00b0C. After sufficient stripping, the trap is warmed to release CFCs, which are then routed into a GC for analysis. Both packed and capillary columns have been used and typically CFC\u201111, CFC\u201112, and CFC\u2011113 can be analyzed in a single run. Because of the possibility of sample contamination during sampling, CFCs are often analyzed in triplicate or more.<\/p>\n<\/div>\n<\/div>\n","protected":false},"author":7,"menu_order":31,"template":"","meta":{"pb_show_title":"on","pb_short_title":"","pb_subtitle":"","pb_authors":[],"pb_section_license":""},"chapter-type":[],"contributor":[],"license":[],"class_list":["post-125","chapter","type-chapter","status-publish","hentry"],"part":35,"_links":{"self":[{"href":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-json\/pressbooks\/v2\/chapters\/125","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-json\/pressbooks\/v2\/chapters"}],"about":[{"href":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-json\/wp\/v2\/types\/chapter"}],"author":[{"embeddable":true,"href":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-json\/wp\/v2\/users\/7"}],"version-history":[{"count":3,"href":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-json\/pressbooks\/v2\/chapters\/125\/revisions"}],"predecessor-version":[{"id":421,"href":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-json\/pressbooks\/v2\/chapters\/125\/revisions\/421"}],"part":[{"href":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-json\/pressbooks\/v2\/parts\/35"}],"metadata":[{"href":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-json\/pressbooks\/v2\/chapters\/125\/metadata\/"}],"wp:attachment":[{"href":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-json\/wp\/v2\/media?parent=125"}],"wp:term":[{"taxonomy":"chapter-type","embeddable":true,"href":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-json\/pressbooks\/v2\/chapter-type?post=125"},{"taxonomy":"contributor","embeddable":true,"href":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-json\/wp\/v2\/contributor?post=125"},{"taxonomy":"license","embeddable":true,"href":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-json\/wp\/v2\/license?post=125"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}