{"id":129,"date":"2026-04-10T02:53:10","date_gmt":"2026-04-10T02:53:10","guid":{"rendered":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/chapter\/ch050-xhtml\/"},"modified":"2026-05-11T22:27:09","modified_gmt":"2026-05-11T22:27:09","slug":"6-6-discussion-of-tracer-specific-issues","status":"publish","type":"chapter","link":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/chapter\/6-6-discussion-of-tracer-specific-issues\/","title":{"raw":"6.6 Discussion of Tracer-Specific Issues","rendered":"6.6 Discussion of Tracer-Specific Issues"},"content":{"raw":"<div id=\"discussion-of-tracer-specific-issues-1\" class=\"level1\">\r\n<div data-custom-style=\"First Paragraph\">\r\n\r\nThe CFC dating method is conceptually straightforward but depends on assumptions such as conservative geochemical behavior in the subsurface and the atmosphere being the only source for CFCs in groundwater. In addition, the reduction of CFC atmospheric concentration since the late 1990s results in a non\u2011uniqueness in the age\u2011concentrations relationship. These issues are briefly discussed in this section.\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nTo function as age\u2011dating tracers, CFC concentrations in groundwater cannot be altered by biogeochemical processes in the subsurface. Minimal sorption of CFCs has been demonstrated in column experiments consisting of ground Ottawa sand (Ciccioli et al., 1980) and CFCs may be considered stable with respect to microbial degradation under aerobic conditions (Lovely &amp; Woodward, 1992). However, for soils and sediments containing modest <em>fractions of organic carbon<\/em> (e.g., foc\u00a0&gt;\u00a00.03 percent) and under reducing conditions, both sorption and microbial degradation can strongly affect CFC concentrations.\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nIn general, CFC\u201112 is the least affected by these processes and comparisons of tracer ages derived from the different CFCs have been used to identify biogeochemical processes affecting CFC\u201111 and CFC\u2011113 (Cook et al., 1995). In laboratory studies, for example, Archbold and others (2012) showed that both CFC\u201111 and CFC\u2011113 degraded in the presence of zero\u2011valent iron with half\u2011lives of less than one day. In a field study, Cook and others (1995) showed stability of CFC\u201112 but almost complete degradation of CFC\u201111 and modest sorption of CFC\u2011113 in a sandy aquifer near Sturgeon Falls, Ontario, Canada. As a general guide, CFC\u201111 tends to be most affected by microbial degradation under anerobic conditions whereas CFC\u2011113 is most affected by sorption onto organic matter in soils and sediments.\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nContamination of groundwater samples by sources other than the atmosphere can alter CFC concentrations in groundwater. Although the absolute concentration from other sources is often small, it can result in values that exceed atmospheric solubility and make dating impossible. Contamination sources include seepage from septic tanks, landfills, releases from polyurethane foam waste, leaky sewer lines, leakage from underground storage tanks, and recharge from rivers that are contaminated with CFCs, often from sewage effluents (Cook, Plummer, et al., 2006). Samples for CFC analyses can also become contaminated during collection, often when plastics are used in the collection process. While sampling equipment such as plastic discharge lines may not inherently contain CFCs, their exposure to the modern atmosphere along with slow desorption into groundwater samples can lead to contamination. When measured concentrations exceed atmospheric solubility, it is easy to recognize such contamination but identifying trace amounts of CFCs that simply elevate groundwater concentrations is difficult. Eliminating the possibility of contamination during sampling\u2014using proper materials and abundant flushing\u2014is extremely important.\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nAs shown in <a href=\"\/age-dating-young-groundwater\/chapter\/6-1-background-and-historical-development\/#figure-24\"><span data-custom-style=\"Hyperlink\">Figure 24<\/span><\/a>, atmospheric concentrations of CFCs started declining in the late 1990s to early 2000s, resulting in a non\u2011uniqueness in the relationship between age and concentration. Although dating waters that recharged since 2000 is problematic with CFCs, it is still possible to date waters that recharged between about 1950 and 2000. In the future, it may be possible to date young waters using the declining limb of the atmospheric curve along with some other tracer and\/or hydrogeologic information that identifies the water as being recharged after about 2000.\r\n\r\n<\/div>\r\n<\/div>","rendered":"<div id=\"discussion-of-tracer-specific-issues-1\" class=\"level1\">\n<div data-custom-style=\"First Paragraph\">\n<p>The CFC dating method is conceptually straightforward but depends on assumptions such as conservative geochemical behavior in the subsurface and the atmosphere being the only source for CFCs in groundwater. In addition, the reduction of CFC atmospheric concentration since the late 1990s results in a non\u2011uniqueness in the age\u2011concentrations relationship. These issues are briefly discussed in this section.<\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>To function as age\u2011dating tracers, CFC concentrations in groundwater cannot be altered by biogeochemical processes in the subsurface. Minimal sorption of CFCs has been demonstrated in column experiments consisting of ground Ottawa sand (Ciccioli et al., 1980) and CFCs may be considered stable with respect to microbial degradation under aerobic conditions (Lovely &amp; Woodward, 1992). However, for soils and sediments containing modest <em>fractions of organic carbon<\/em> (e.g., foc\u00a0&gt;\u00a00.03 percent) and under reducing conditions, both sorption and microbial degradation can strongly affect CFC concentrations.<\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>In general, CFC\u201112 is the least affected by these processes and comparisons of tracer ages derived from the different CFCs have been used to identify biogeochemical processes affecting CFC\u201111 and CFC\u2011113 (Cook et al., 1995). In laboratory studies, for example, Archbold and others (2012) showed that both CFC\u201111 and CFC\u2011113 degraded in the presence of zero\u2011valent iron with half\u2011lives of less than one day. In a field study, Cook and others (1995) showed stability of CFC\u201112 but almost complete degradation of CFC\u201111 and modest sorption of CFC\u2011113 in a sandy aquifer near Sturgeon Falls, Ontario, Canada. As a general guide, CFC\u201111 tends to be most affected by microbial degradation under anerobic conditions whereas CFC\u2011113 is most affected by sorption onto organic matter in soils and sediments.<\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>Contamination of groundwater samples by sources other than the atmosphere can alter CFC concentrations in groundwater. Although the absolute concentration from other sources is often small, it can result in values that exceed atmospheric solubility and make dating impossible. Contamination sources include seepage from septic tanks, landfills, releases from polyurethane foam waste, leaky sewer lines, leakage from underground storage tanks, and recharge from rivers that are contaminated with CFCs, often from sewage effluents (Cook, Plummer, et al., 2006). Samples for CFC analyses can also become contaminated during collection, often when plastics are used in the collection process. While sampling equipment such as plastic discharge lines may not inherently contain CFCs, their exposure to the modern atmosphere along with slow desorption into groundwater samples can lead to contamination. When measured concentrations exceed atmospheric solubility, it is easy to recognize such contamination but identifying trace amounts of CFCs that simply elevate groundwater concentrations is difficult. Eliminating the possibility of contamination during sampling\u2014using proper materials and abundant flushing\u2014is extremely important.<\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>As shown in <a href=\"\/age-dating-young-groundwater\/chapter\/6-1-background-and-historical-development\/#figure-24\"><span data-custom-style=\"Hyperlink\">Figure 24<\/span><\/a>, atmospheric concentrations of CFCs started declining in the late 1990s to early 2000s, resulting in a non\u2011uniqueness in the relationship between age and concentration. Although dating waters that recharged since 2000 is problematic with CFCs, it is still possible to date waters that recharged between about 1950 and 2000. In the future, it may be possible to date young waters using the declining limb of the atmospheric curve along with some other tracer and\/or hydrogeologic information that identifies the water as being recharged after about 2000.<\/p>\n<\/div>\n<\/div>\n","protected":false},"author":7,"menu_order":34,"template":"","meta":{"pb_show_title":"on","pb_short_title":"","pb_subtitle":"","pb_authors":[],"pb_section_license":""},"chapter-type":[],"contributor":[],"license":[],"class_list":["post-129","chapter","type-chapter","status-publish","hentry"],"part":35,"_links":{"self":[{"href":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-json\/pressbooks\/v2\/chapters\/129","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-json\/pressbooks\/v2\/chapters"}],"about":[{"href":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-json\/wp\/v2\/types\/chapter"}],"author":[{"embeddable":true,"href":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-json\/wp\/v2\/users\/7"}],"version-history":[{"count":2,"href":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-json\/pressbooks\/v2\/chapters\/129\/revisions"}],"predecessor-version":[{"id":419,"href":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-json\/pressbooks\/v2\/chapters\/129\/revisions\/419"}],"part":[{"href":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-json\/pressbooks\/v2\/parts\/35"}],"metadata":[{"href":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-json\/pressbooks\/v2\/chapters\/129\/metadata\/"}],"wp:attachment":[{"href":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-json\/wp\/v2\/media?parent=129"}],"wp:term":[{"taxonomy":"chapter-type","embeddable":true,"href":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-json\/pressbooks\/v2\/chapter-type?post=129"},{"taxonomy":"contributor","embeddable":true,"href":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-json\/wp\/v2\/contributor?post=129"},{"taxonomy":"license","embeddable":true,"href":"https:\/\/books.gw-project.org\/age-dating-young-groundwater\/wp-json\/wp\/v2\/license?post=129"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}