{"id":1695,"date":"2026-02-14T04:24:23","date_gmt":"2026-02-14T04:24:23","guid":{"rendered":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/chapter\/ch050-xhtml\/"},"modified":"2026-08-01T09:27:13","modified_gmt":"2026-08-01T09:27:13","slug":"computing-t-and-s-from-aquifer-test-data","status":"publish","type":"chapter","link":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/chapter\/computing-t-and-s-from-aquifer-test-data\/","title":{"raw":"10.4 Computing T and S from Aquifer Test Data","rendered":"10.4 Computing T and S from Aquifer Test Data"},"content":{"raw":"<div id=\"computing-t-and-s-from-aquifer-test-data\" class=\"level1\">\r\n<div data-custom-style=\"First Paragraph\">\r\n<div data-custom-style=\"First Paragraph\">\r\n\r\nCurve matching and numerical methods are used to match field time\u2011drawdown data with analytical solutions that use <em>u<sub>a<\/sub><\/em>, u<em><sub>y<\/sub><\/em>, <em>\u03b7<\/em> and W(<em>u<sub>a<\/sub><\/em>,<em>u<sub>y<\/sub><\/em>,<em>\u03b7<\/em>). Curve matching techniques described in Section 8.3.1 are applicable here. Neuman\u2019s representation of the instantaneous release of water from storage assumptions result in poor values of <em>S<\/em> that are usually higher than the field value of the early\u2011time confined storage, and lower than the field value for the late\u2011time specific yield. The transmissivity values obtained using Neuman's techniques are considered representative of field properties. Nwankwor and others (1992) recommend <em>S<sub>y<\/sub><\/em> should only be computed from late time test data citing the need for at least a three\u2011day pumping test.\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nAgain, to build a basic understanding of the methods used to analyze field data, a description of the manual approach is presented in this section. When the values in <a href=\"\/an-introduction-to-hydraulic-testing-in-hydrogeology\/chapter\/formulating-delayed-yield-analysis\/#X5ed5973b5d6fc0becf45894a31bfc115c33b585\">Figure 60<\/a> and <a href=\"\/an-introduction-to-hydraulic-testing-in-hydrogeology\/chapter\/formulating-delayed-yield-analysis\/#X803a08d1c2133be2fd543074b7e40d9374f49bb\">Figure 61<\/a> are plotted on log\u2011log scales a family of curves is created. These type curves are a bit complicated, as values of W(<em>u<sub>a,<\/sub>u<sub>y<\/sub><\/em>,<em>\u03b7<\/em>) are plotted on the vertical axis, values of 1\/<em>u<sub>a<\/sub><\/em> are plotted on the top x axis, values of 1\/<em>u<sub>y<\/sub><\/em> are plotted on the lower x axis, and a family of curves are derived for values of <em>\u03b7<\/em>. In addition, the Theis curves for confined conditions (<em>S<\/em>) and unconfined conditions (<em>S<sub>y<\/sub><\/em>) are also plotted (<a href=\"#X2f77bd5ad48b2bfc563714cee71eac1620fbac8\">Figure 62<\/a>).\r\n\r\n<\/div>\r\n<div class=\"bc-figure figure\" data-custom-style=\"Captioned Figure\"><img style=\"display: block; margin-left: auto; margin-right: auto; ;width: 5.83333in; height: 3.50133in;\" src=\"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-content\/uploads\/sites\/40\/2026\/08\/file66-1.jpg\" alt=\"\" \/>\r\n<div class=\"bc-figcaption figcaption\">\r\n<div data-custom-style=\"Image Caption\">\r\n<div class=\"figcaption-text\">\r\n\r\n<span id=\"X2f77bd5ad48b2bfc563714cee71eac1620fbac8\" class=\"anchor\"><strong>Figure 62 \u2011<\/strong> Neuman type curves for unconfined systems with delayed yield (Todd and Mays, 2005).<\/span>\r\n\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nWhen a delayed yield is observed in drawdown data from an unconfined pumping test (<a href=\"#Xcafbbd9ba4c52f7001c9fdaa2ff82a10957f7dc\">Figure 63<\/a>), curve matching is a two\u2011step process (<a href=\"#X414fef407a3e6a68430e2fc1123cf2adc2611f9\">Figure 64<\/a> and <a href=\"#X7329eacce2995531ac62671d0dda138ddc2ec52\">Figure 65<\/a>).\r\n\r\n<\/div>\r\n<div data-custom-style=\"Captioned Figure\">\r\n\r\n<img style=\"display: block; margin-left: auto; margin-right: auto; ;width: 5.5in; height: 3.39in;\" src=\"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-content\/uploads\/sites\/40\/2026\/08\/file67-1.jpg\" alt=\"\" \/>\r\n\r\n<\/div>\r\n<div data-custom-style=\"Block Text\">\r\n<blockquote>\r\n<div class=\"figcaption-text\">\r\n\r\n<span id=\"Xcafbbd9ba4c52f7001c9fdaa2ff82a10957f7dc\" class=\"anchor\"><strong>Figure 63 \u2011<\/strong> An example of a log\u2011log time\u2011drawdown plot of field data (solid red dots) collected at an observation well in an unconfined aquifer being pumped at a constant rate.<\/span>\r\n\r\n<\/div><\/blockquote>\r\n<\/div>\r\n<div class=\"bc-figure figure\" data-custom-style=\"Captioned Figure\"><img style=\"display: block; margin-left: auto; margin-right: auto; ;width: 5.83333in; height: 3.62986in;\" src=\"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-content\/uploads\/sites\/40\/2026\/08\/file68-1.jpg\" alt=\"\" \/>\r\n<div class=\"bc-figcaption figcaption\">\r\n<div data-custom-style=\"Image Caption\">\r\n<div class=\"figcaption-text\">\r\n\r\n<span id=\"X414fef407a3e6a68430e2fc1123cf2adc2611f9\" class=\"anchor\"><strong>Figure 64 \u2011<\/strong> Matching early time\u2011drawdown data with Neuman\u2019s (1975) unconfined delayed yield type curves.<\/span>\r\n\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<div class=\"bc-figure figure\" data-custom-style=\"Captioned Figure\"><img style=\"display: block; margin-left: auto; margin-right: auto; ;width: 5.83333in; height: 3.6297in;\" src=\"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-content\/uploads\/sites\/40\/2026\/08\/file69-1.jpg\" alt=\"\" \/>\r\n<div class=\"bc-figcaption figcaption\">\r\n<div data-custom-style=\"Image Caption\">\r\n<div class=\"figcaption-text\">\r\n\r\n<span id=\"X7329eacce2995531ac62671d0dda138ddc2ec52\" class=\"anchor\"><strong>Figure 65 \u2011<\/strong> Matching late time\u2011drawdown data with Neuman\u2019s (1975) unconfined delayed yield type curves.<\/span>\r\n\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nStandard curve matching procedures are applied. Plots are prepared using identical log\u2011log scales and axes are kept parallel. The first step is to match the early\u2011time data with the left\u2011hand portion of <a href=\"#X2f77bd5ad48b2bfc563714cee71eac1620fbac8\">Figure 62<\/a>. A match point is selected using the top x\u2011axis (1\/<em>u<sub>a<\/sub><\/em>) and the left vertical scale (W(<em>u<sub>a<\/sub><\/em>,<em>u<sub>y<\/sub><\/em>,<em>\u03b7<\/em>). Then <em>s<\/em> and <em>t<\/em> values are obtained from the drawdown plot, and the <em>\u03b7<\/em> curve value is noted (<a href=\"#X414fef407a3e6a68430e2fc1123cf2adc2611f9\">Figure 64<\/a>). When delayed yield is affecting the drawdown data, the complete type curve plot (<a href=\"#X414fef407a3e6a68430e2fc1123cf2adc2611f9\">Figure 64<\/a>) is not treated as continuous because the periods of delayed yield are variable and aquifer specific. The second step is to slide the data plot to the right along the <em>\u03b7<\/em> curve used to match the early data and determine the best match to the late time data (<a href=\"#X7329eacce2995531ac62671d0dda138ddc2ec52\">Figure 65<\/a>). The data matches should be on the same <em>\u03b7<\/em> curve. The late\u2011time data are matched, and a second match point is selected. The late\u2011time match point includes 1\/<em>u<sub>y<\/sub><\/em> taken from the lower x\u2011axis, W(<em>u<sub>a<\/sub><\/em>,<em>u<sub>y<\/sub><\/em>,<em>\u03b7<\/em>) from the vertical axis, <em>s<\/em> and <em>t<\/em> from the time\u2011drawdown curve, and the value of the <em>\u03b7<\/em> curve.\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nWhen <em>T<\/em> is calculated for both the early\u2011 and late\u2011time data, values are usually very similar. Values are averaged to determine a representative value. As stated earlier, <em>S<\/em> values are often poorly represented (as shown in the example below). Thus, storage values obtained by curve matching are often replaced with lab or literature\u2011derived values are used to represent the unconfined aquifer instead of computed values (e.g., Box 2 of this book, as well as Woessner &amp; Poeter, 2020). Analyzing time drawdown data for an extended period after the delayed\u2011yield portion of the response dissipates is recommended to generate more representative specific yield values form late\u2011time data.\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nTransmissivity is computed by rearranging Equation\u00a0<a href=\"\/an-introduction-to-hydraulic-testing-in-hydrogeology\/chapter\/formulating-delayed-yield-analysis\/#X4e131665c659d04cd3eb9768ac79e55f5ad8ba3\">(70)<\/a> to Equation\u00a0<a href=\"#Xfe7346c9d0a4d2b80f983c4f6dd5ae15cdfa251\">(74)<\/a>. Storativity values are calculated by solving for S and S<em><sub>y<\/sub><\/em> in Equations <a href=\"\/an-introduction-to-hydraulic-testing-in-hydrogeology\/chapter\/formulating-delayed-yield-analysis\/#X0a5a3569ffd3738d4430c88ed03bb26cd312690\">(71)<\/a> and <a href=\"\/an-introduction-to-hydraulic-testing-in-hydrogeology\/chapter\/formulating-delayed-yield-analysis\/#X0b410a45c47df65a5402f75b0f9cc99bea75ea1\">(72)<\/a>. The horizontal hydraulic conductivity can be estimated as <em>T<\/em>\/<em>b<\/em> and the vertical hydraulic conductivity can be obtained by rearranging Equation\u00a0<a href=\"\/an-introduction-to-hydraulic-testing-in-hydrogeology\/chapter\/formulating-delayed-yield-analysis\/#Xc5aa6d4dcde6806a0ce4e6a17bac04d6b244544\">(73)<\/a> to Equation\u00a0<a href=\"#X4322394716e08947e156007088e9fb58ac9e453\">(78)<\/a>.\r\n\r\n<\/div>\r\n<table class=\"gw-eq-table\" style=\"width: 100%;\" data-custom-style=\"Table\"><colgroup> <col style=\"width: 10%;\" \/> <col style=\"width: 75%;\" \/> <col style=\"width: 15%;\" \/><\/colgroup>\r\n<tbody>\r\n<tr>\r\n<th><\/th>\r\n<th style=\"text-align: center;\">[latex]T = \\frac{Q}{4\\pi s}\\ W\\left( u_{a},u_{y,}\\eta \\right)[\/latex]<\/th>\r\n<th style=\"text-align: right; white-space: nowrap;\"><span id=\"Xfe7346c9d0a4d2b80f983c4f6dd5ae15cdfa251\" class=\"anchor\">(74)<\/span><\/th>\r\n<\/tr>\r\n<tr>\r\n<td><\/td>\r\n<td style=\"text-align: center;\">[latex]\\frac{u_{a}4Tt}{r^{2}} = S[\/latex]<\/td>\r\n<td style=\"text-align: right; white-space: nowrap;\"><span id=\"Xc955a151795a3165fb856990d35d57f607bf50e\" class=\"anchor\">(75)<\/span><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><\/td>\r\n<td style=\"text-align: center;\">[latex]\\frac{u_{y}4Tt}{r^{2}} = S_{y}[\/latex]<\/td>\r\n<td style=\"text-align: right; white-space: nowrap;\"><span id=\"Xf8359b96e0ffc9e0f8f7cd1c62dd7e2fc5a133e\" class=\"anchor\">(76)<\/span><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><\/td>\r\n<td style=\"text-align: center;\">[latex]\\frac{T}{b} = K[\/latex]<\/td>\r\n<td style=\"text-align: right; white-space: nowrap;\"><span id=\"X7b78df277ba5e1d2954b8f19d4b1f256cef6e3d\" class=\"anchor\">(77)<\/span><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><\/td>\r\n<td style=\"text-align: center;\">[latex]\\frac{\\eta b^{2}K_{h}}{r^{2}} = K_{z}[\/latex]<\/td>\r\n<td style=\"text-align: right; white-space: nowrap;\"><span id=\"X4322394716e08947e156007088e9fb58ac9e453\" class=\"anchor\">(78)<\/span><\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nwhere:\r\n\r\n<\/div>\r\n<table style=\"width: 85%;\" data-custom-style=\"Table\"><colgroup> <col style=\"width: 14%;\" \/> <col style=\"width: 3%;\" \/> <col style=\"width: 67%;\" \/> <\/colgroup>\r\n<thead>\r\n<tr>\r\n<th style=\"text-align: right;\"><em>s<\/em>(<em>r<\/em>,<em>t<\/em>)<\/th>\r\n<th style=\"text-align: center;\">=<\/th>\r\n<th>drawdown at a radial distance <em>r<\/em> and time <em>t<\/em> (L)<\/th>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr>\r\n<td style=\"text-align: right;\"><em>Q<\/em><\/td>\r\n<td style=\"text-align: center;\">=<\/td>\r\n<td>constant well discharge rate (L<sup>3<\/sup>T<sup>\u20111<\/sup>)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"text-align: right;\"><em>T<\/em><\/td>\r\n<td style=\"text-align: center;\">=<\/td>\r\n<td>transmissivity (L<sup>2<\/sup>T<sup>\u20111<\/sup>)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"text-align: right;\"><em>S<\/em><\/td>\r\n<td style=\"text-align: center;\">=<\/td>\r\n<td>storativity under early time confined conditions (dimensionless)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"text-align: right;\"><em>S<sub>y<\/sub><\/em><\/td>\r\n<td style=\"text-align: center;\">=<\/td>\r\n<td>storativity at late times, specific yield (dimensionless)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"text-align: right;\"><em>t<\/em><\/td>\r\n<td style=\"text-align: center;\">=<\/td>\r\n<td>time (T)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"text-align: right;\"><em>r<\/em><\/td>\r\n<td style=\"text-align: center;\">=<\/td>\r\n<td>radial distance to the observation well (L)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"text-align: right;\"><em>u<sub>a<\/sub><\/em><\/td>\r\n<td style=\"text-align: center;\">=<\/td>\r\n<td>early time values of <em>u<\/em> (dimensionless)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"text-align: right;\"><em>u<sub>y<\/sub><\/em><\/td>\r\n<td style=\"text-align: center;\">=<\/td>\r\n<td>late time values of <em>u<\/em> (dimensionless)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"text-align: right;\">W(<em>u<sub>a<\/sub><\/em>,<em>u<sub>y<\/sub><\/em>,<em>\u03b7<\/em>)<\/td>\r\n<td style=\"text-align: center;\">=<\/td>\r\n<td>unconfined well function (dimensionless)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"text-align: right;\"><em>K<sub>z<\/sub><\/em><\/td>\r\n<td style=\"text-align: center;\">=<\/td>\r\n<td>unconfined vertical hydraulic conductivity (LT<sup>\u20111<\/sup>)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"text-align: right;\"><em>K<sub>h<\/sub><\/em><\/td>\r\n<td style=\"text-align: center;\">=<\/td>\r\n<td>unconfined horizontal hydraulic conductivity (LT<sup>\u20111<\/sup>)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"text-align: right;\"><em>b<\/em><\/td>\r\n<td style=\"text-align: center;\">=<\/td>\r\n<td>pre\u2011pumping saturated thickness (L)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"text-align: right;\"><em>\u03b7<\/em><\/td>\r\n<td style=\"text-align: center;\">=<\/td>\r\n<td>variable defined by Equation\u00a0<a href=\"\/an-introduction-to-hydraulic-testing-in-hydrogeology\/chapter\/formulating-delayed-yield-analysis\/#Xc5aa6d4dcde6806a0ce4e6a17bac04d6b244544\">(73)<\/a> (dimensionless)<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<div data-custom-style=\"Body Text\">\r\n\r\n<strong>Example<\/strong>\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\n<em>T<\/em>, <em>S<\/em>, and <em>S<sub>y <\/sub><\/em>can be estimated using the match points (<a href=\"#X414fef407a3e6a68430e2fc1123cf2adc2611f9\">Figure 64<\/a> and <a href=\"#X7329eacce2995531ac62671d0dda138ddc2ec52\">Figure 65<\/a>) if it is assumed that the data represented in <a href=\"#Xcafbbd9ba4c52f7001c9fdaa2ff82a10957f7dc\">Figure 63<\/a> were collected at an observation well located 120 m from the pumping well during a 4\u2011day hydraulic test with a well pumping at 4,000 m<sup>3<\/sup>\/d. The aquifer has a pre\u2011pumping saturated thickness of 28 m and is sand and gravel. Match point data in <a href=\"#X414fef407a3e6a68430e2fc1123cf2adc2611f9\">Figure 64<\/a> are used to compute the transmissivity from early\u2011time data using Equation\u00a0<a href=\"#Xfe7346c9d0a4d2b80f983c4f6dd5ae15cdfa251\">(74)<\/a> and storativity using Equation\u00a0<a href=\"#Xc955a151795a3165fb856990d35d57f607bf50e\">(75)<\/a>.\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n<div class=\"display-math\" data-custom-style=\"Display Equation\">\r\n\r\n[latex]T = \\frac{4000\\frac{m^{3}}{d}}{4\\ (3.14)\\ 1\\ m}\\ (1) = 318\\frac{m^{2}}{d}[\/latex]\r\n\r\n<\/div>\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n<div class=\"display-math\" data-custom-style=\"Display Equation\">\r\n\r\n[latex]S = \\frac{(1)\\ 4\\ \\left( 318\\frac{\\ m^{2}}{d} \\right)0.0005\\ d}{{(120\\ m)}^{2}} = 0.000044\\ \\ or\\ \\ 4.4{x10}^{- 5}[\/latex]\r\n\r\n<\/div>\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nUsing the late time match point of <a href=\"#X7329eacce2995531ac62671d0dda138ddc2ec52\">Figure 65<\/a> and Equations <a href=\"#Xfe7346c9d0a4d2b80f983c4f6dd5ae15cdfa251\">(74)<\/a> and <a href=\"#Xf8359b96e0ffc9e0f8f7cd1c62dd7e2fc5a133e\">(76)<\/a>, transmissivity and specific yield are calculated.\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n<div class=\"display-math\" data-custom-style=\"Display Equation\">\r\n\r\n[latex]T = \\frac{4000\\frac{m^{3}}{d}}{4\\ (3.14)\\ 0.98\\ m}\\ (1) = 325\\frac{m^{2}}{d}[\/latex]\r\n\r\n<\/div>\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n<div class=\"display-math\" data-custom-style=\"Display Equation\">\r\n\r\n[latex]S_{y} = \\frac{(1)\\ 4\\ \\left( 325\\frac{\\ m^{2}}{d} \\right)\\ 0.25\\ d}{{(120\\ m)}^{2}} = 0.02[\/latex]\r\n\r\n<\/div>\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nAveraging the <em>T<\/em> values yields a value of 322 m<sup>2<\/sup>\/d. In this example the confined storage coefficient seems reasonable, but the specific yield is quite small and most likely not representative of field conditions. This suggests that analytical formulations may not fully capture the release of water as the aquifer dewaters.\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nThe horizontal hydraulic conductivity is computed using Equation\u00a0<a href=\"#X7b78df277ba5e1d2954b8f19d4b1f256cef6e3d\">(77)<\/a>\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n<div class=\"display-math\" data-custom-style=\"Display Equation\">\r\n\r\n[latex]\\frac{322\\frac{\\ m^{2}}{d}}{28\\ m} = 11.5\\ \\frac{m}{d}[\/latex]\r\n\r\n<\/div>\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nNext using Equation\u00a0<a href=\"#X4322394716e08947e156007088e9fb58ac9e453\">(78)<\/a> and match point value of <em>\u03b7<\/em> =2.0, vertical hydraulic conductivity is calculated.\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n<div class=\"display-math\" data-custom-style=\"Display Equation\">\r\n\r\n[latex]K_{z} = \\frac{(1)\\ 2.0\\ {(28\\ m)}^{2}\\ \\ 11.5\\ \\frac{m}{d}}{{(120\\ m)}^{2}} = 1.3\\frac{m}{d}[\/latex]\r\n\r\n<\/div>\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nAnalytical approaches to describing the response of wells when pumping an unconfined system were outlined in this section. Numerical methods can also be used to approximate the response of unconfined aquifers to pumping. However, representation of delayed yield processes requires additional model complexity (e.g., Anderson et al., 2015; Diersch, 2014).\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nSection\u00a011 presents methods to assess how boundaries, well interference, and anisotropy affect efforts to forecast drawdowns and estimate hydrogeologic properties.\r\n\r\n<\/div>\r\n<\/div>\r\n<\/div>","rendered":"<div id=\"computing-t-and-s-from-aquifer-test-data\" class=\"level1\">\n<div data-custom-style=\"First Paragraph\">\n<div data-custom-style=\"First Paragraph\">\n<p>Curve matching and numerical methods are used to match field time\u2011drawdown data with analytical solutions that use <em>u<sub>a<\/sub><\/em>, u<em><sub>y<\/sub><\/em>, <em>\u03b7<\/em> and W(<em>u<sub>a<\/sub><\/em>,<em>u<sub>y<\/sub><\/em>,<em>\u03b7<\/em>). Curve matching techniques described in Section 8.3.1 are applicable here. Neuman\u2019s representation of the instantaneous release of water from storage assumptions result in poor values of <em>S<\/em> that are usually higher than the field value of the early\u2011time confined storage, and lower than the field value for the late\u2011time specific yield. The transmissivity values obtained using Neuman&#8217;s techniques are considered representative of field properties. Nwankwor and others (1992) recommend <em>S<sub>y<\/sub><\/em> should only be computed from late time test data citing the need for at least a three\u2011day pumping test.<\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>Again, to build a basic understanding of the methods used to analyze field data, a description of the manual approach is presented in this section. When the values in <a href=\"\/an-introduction-to-hydraulic-testing-in-hydrogeology\/chapter\/formulating-delayed-yield-analysis\/#X5ed5973b5d6fc0becf45894a31bfc115c33b585\">Figure 60<\/a> and <a href=\"\/an-introduction-to-hydraulic-testing-in-hydrogeology\/chapter\/formulating-delayed-yield-analysis\/#X803a08d1c2133be2fd543074b7e40d9374f49bb\">Figure 61<\/a> are plotted on log\u2011log scales a family of curves is created. These type curves are a bit complicated, as values of W(<em>u<sub>a,<\/sub>u<sub>y<\/sub><\/em>,<em>\u03b7<\/em>) are plotted on the vertical axis, values of 1\/<em>u<sub>a<\/sub><\/em> are plotted on the top x axis, values of 1\/<em>u<sub>y<\/sub><\/em> are plotted on the lower x axis, and a family of curves are derived for values of <em>\u03b7<\/em>. In addition, the Theis curves for confined conditions (<em>S<\/em>) and unconfined conditions (<em>S<sub>y<\/sub><\/em>) are also plotted (<a href=\"#X2f77bd5ad48b2bfc563714cee71eac1620fbac8\">Figure 62<\/a>).<\/p>\n<\/div>\n<div class=\"bc-figure figure\" data-custom-style=\"Captioned Figure\"><img decoding=\"async\" style=\"display: block; margin-left: auto; margin-right: auto; ;width: 5.83333in; height: 3.50133in;\" src=\"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-content\/uploads\/sites\/40\/2026\/08\/file66-1.jpg\" alt=\"\" \/><\/p>\n<div class=\"bc-figcaption figcaption\">\n<div data-custom-style=\"Image Caption\">\n<div class=\"figcaption-text\">\n<p><span id=\"X2f77bd5ad48b2bfc563714cee71eac1620fbac8\" class=\"anchor\"><strong>Figure 62 \u2011<\/strong> Neuman type curves for unconfined systems with delayed yield (Todd and Mays, 2005).<\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>When a delayed yield is observed in drawdown data from an unconfined pumping test (<a href=\"#Xcafbbd9ba4c52f7001c9fdaa2ff82a10957f7dc\">Figure 63<\/a>), curve matching is a two\u2011step process (<a href=\"#X414fef407a3e6a68430e2fc1123cf2adc2611f9\">Figure 64<\/a> and <a href=\"#X7329eacce2995531ac62671d0dda138ddc2ec52\">Figure 65<\/a>).<\/p>\n<\/div>\n<div data-custom-style=\"Captioned Figure\">\n<p><img decoding=\"async\" style=\"display: block; margin-left: auto; margin-right: auto; ;width: 5.5in; height: 3.39in;\" src=\"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-content\/uploads\/sites\/40\/2026\/08\/file67-1.jpg\" alt=\"\" \/><\/p>\n<\/div>\n<div data-custom-style=\"Block Text\">\n<blockquote>\n<div class=\"figcaption-text\">\n<p><span id=\"Xcafbbd9ba4c52f7001c9fdaa2ff82a10957f7dc\" class=\"anchor\"><strong>Figure 63 \u2011<\/strong> An example of a log\u2011log time\u2011drawdown plot of field data (solid red dots) collected at an observation well in an unconfined aquifer being pumped at a constant rate.<\/span><\/p>\n<\/div>\n<\/blockquote>\n<\/div>\n<div class=\"bc-figure figure\" data-custom-style=\"Captioned Figure\"><img decoding=\"async\" style=\"display: block; margin-left: auto; margin-right: auto; ;width: 5.83333in; height: 3.62986in;\" src=\"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-content\/uploads\/sites\/40\/2026\/08\/file68-1.jpg\" alt=\"\" \/><\/p>\n<div class=\"bc-figcaption figcaption\">\n<div data-custom-style=\"Image Caption\">\n<div class=\"figcaption-text\">\n<p><span id=\"X414fef407a3e6a68430e2fc1123cf2adc2611f9\" class=\"anchor\"><strong>Figure 64 \u2011<\/strong> Matching early time\u2011drawdown data with Neuman\u2019s (1975) unconfined delayed yield type curves.<\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"bc-figure figure\" data-custom-style=\"Captioned Figure\"><img decoding=\"async\" style=\"display: block; margin-left: auto; margin-right: auto; ;width: 5.83333in; height: 3.6297in;\" src=\"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-content\/uploads\/sites\/40\/2026\/08\/file69-1.jpg\" alt=\"\" \/><\/p>\n<div class=\"bc-figcaption figcaption\">\n<div data-custom-style=\"Image Caption\">\n<div class=\"figcaption-text\">\n<p><span id=\"X7329eacce2995531ac62671d0dda138ddc2ec52\" class=\"anchor\"><strong>Figure 65 \u2011<\/strong> Matching late time\u2011drawdown data with Neuman\u2019s (1975) unconfined delayed yield type curves.<\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>Standard curve matching procedures are applied. Plots are prepared using identical log\u2011log scales and axes are kept parallel. The first step is to match the early\u2011time data with the left\u2011hand portion of <a href=\"#X2f77bd5ad48b2bfc563714cee71eac1620fbac8\">Figure 62<\/a>. A match point is selected using the top x\u2011axis (1\/<em>u<sub>a<\/sub><\/em>) and the left vertical scale (W(<em>u<sub>a<\/sub><\/em>,<em>u<sub>y<\/sub><\/em>,<em>\u03b7<\/em>). Then <em>s<\/em> and <em>t<\/em> values are obtained from the drawdown plot, and the <em>\u03b7<\/em> curve value is noted (<a href=\"#X414fef407a3e6a68430e2fc1123cf2adc2611f9\">Figure 64<\/a>). When delayed yield is affecting the drawdown data, the complete type curve plot (<a href=\"#X414fef407a3e6a68430e2fc1123cf2adc2611f9\">Figure 64<\/a>) is not treated as continuous because the periods of delayed yield are variable and aquifer specific. The second step is to slide the data plot to the right along the <em>\u03b7<\/em> curve used to match the early data and determine the best match to the late time data (<a href=\"#X7329eacce2995531ac62671d0dda138ddc2ec52\">Figure 65<\/a>). The data matches should be on the same <em>\u03b7<\/em> curve. The late\u2011time data are matched, and a second match point is selected. The late\u2011time match point includes 1\/<em>u<sub>y<\/sub><\/em> taken from the lower x\u2011axis, W(<em>u<sub>a<\/sub><\/em>,<em>u<sub>y<\/sub><\/em>,<em>\u03b7<\/em>) from the vertical axis, <em>s<\/em> and <em>t<\/em> from the time\u2011drawdown curve, and the value of the <em>\u03b7<\/em> curve.<\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>When <em>T<\/em> is calculated for both the early\u2011 and late\u2011time data, values are usually very similar. Values are averaged to determine a representative value. As stated earlier, <em>S<\/em> values are often poorly represented (as shown in the example below). Thus, storage values obtained by curve matching are often replaced with lab or literature\u2011derived values are used to represent the unconfined aquifer instead of computed values (e.g., Box 2 of this book, as well as Woessner &amp; Poeter, 2020). Analyzing time drawdown data for an extended period after the delayed\u2011yield portion of the response dissipates is recommended to generate more representative specific yield values form late\u2011time data.<\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>Transmissivity is computed by rearranging Equation\u00a0<a href=\"\/an-introduction-to-hydraulic-testing-in-hydrogeology\/chapter\/formulating-delayed-yield-analysis\/#X4e131665c659d04cd3eb9768ac79e55f5ad8ba3\">(70)<\/a> to Equation\u00a0<a href=\"#Xfe7346c9d0a4d2b80f983c4f6dd5ae15cdfa251\">(74)<\/a>. Storativity values are calculated by solving for S and S<em><sub>y<\/sub><\/em> in Equations <a href=\"\/an-introduction-to-hydraulic-testing-in-hydrogeology\/chapter\/formulating-delayed-yield-analysis\/#X0a5a3569ffd3738d4430c88ed03bb26cd312690\">(71)<\/a> and <a href=\"\/an-introduction-to-hydraulic-testing-in-hydrogeology\/chapter\/formulating-delayed-yield-analysis\/#X0b410a45c47df65a5402f75b0f9cc99bea75ea1\">(72)<\/a>. The horizontal hydraulic conductivity can be estimated as <em>T<\/em>\/<em>b<\/em> and the vertical hydraulic conductivity can be obtained by rearranging Equation\u00a0<a href=\"\/an-introduction-to-hydraulic-testing-in-hydrogeology\/chapter\/formulating-delayed-yield-analysis\/#Xc5aa6d4dcde6806a0ce4e6a17bac04d6b244544\">(73)<\/a> to Equation\u00a0<a href=\"#X4322394716e08947e156007088e9fb58ac9e453\">(78)<\/a>.<\/p>\n<\/div>\n<table class=\"gw-eq-table\" style=\"width: 100%;\" data-custom-style=\"Table\">\n<colgroup>\n<col style=\"width: 10%;\" \/>\n<col style=\"width: 75%;\" \/>\n<col style=\"width: 15%;\" \/><\/colgroup>\n<tbody>\n<tr>\n<th><\/th>\n<th style=\"text-align: center;\">[latex]T = \\frac{Q}{4\\pi s}\\ W\\left( u_{a},u_{y,}\\eta \\right)[\/latex]<\/th>\n<th style=\"text-align: right; white-space: nowrap;\"><span id=\"Xfe7346c9d0a4d2b80f983c4f6dd5ae15cdfa251\" class=\"anchor\">(74)<\/span><\/th>\n<\/tr>\n<tr>\n<td><\/td>\n<td style=\"text-align: center;\">[latex]\\frac{u_{a}4Tt}{r^{2}} = S[\/latex]<\/td>\n<td style=\"text-align: right; white-space: nowrap;\"><span id=\"Xc955a151795a3165fb856990d35d57f607bf50e\" class=\"anchor\">(75)<\/span><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td style=\"text-align: center;\">[latex]\\frac{u_{y}4Tt}{r^{2}} = S_{y}[\/latex]<\/td>\n<td style=\"text-align: right; white-space: nowrap;\"><span id=\"Xf8359b96e0ffc9e0f8f7cd1c62dd7e2fc5a133e\" class=\"anchor\">(76)<\/span><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td style=\"text-align: center;\">[latex]\\frac{T}{b} = K[\/latex]<\/td>\n<td style=\"text-align: right; white-space: nowrap;\"><span id=\"X7b78df277ba5e1d2954b8f19d4b1f256cef6e3d\" class=\"anchor\">(77)<\/span><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td style=\"text-align: center;\">[latex]\\frac{\\eta b^{2}K_{h}}{r^{2}} = K_{z}[\/latex]<\/td>\n<td style=\"text-align: right; white-space: nowrap;\"><span id=\"X4322394716e08947e156007088e9fb58ac9e453\" class=\"anchor\">(78)<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div data-custom-style=\"Body Text\">\n<p>where:<\/p>\n<\/div>\n<table style=\"width: 85%;\" data-custom-style=\"Table\">\n<colgroup>\n<col style=\"width: 14%;\" \/>\n<col style=\"width: 3%;\" \/>\n<col style=\"width: 67%;\" \/> <\/colgroup>\n<thead>\n<tr>\n<th style=\"text-align: right;\"><em>s<\/em>(<em>r<\/em>,<em>t<\/em>)<\/th>\n<th style=\"text-align: center;\">=<\/th>\n<th>drawdown at a radial distance <em>r<\/em> and time <em>t<\/em> (L)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: right;\"><em>Q<\/em><\/td>\n<td style=\"text-align: center;\">=<\/td>\n<td>constant well discharge rate (L<sup>3<\/sup>T<sup>\u20111<\/sup>)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right;\"><em>T<\/em><\/td>\n<td style=\"text-align: center;\">=<\/td>\n<td>transmissivity (L<sup>2<\/sup>T<sup>\u20111<\/sup>)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right;\"><em>S<\/em><\/td>\n<td style=\"text-align: center;\">=<\/td>\n<td>storativity under early time confined conditions (dimensionless)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right;\"><em>S<sub>y<\/sub><\/em><\/td>\n<td style=\"text-align: center;\">=<\/td>\n<td>storativity at late times, specific yield (dimensionless)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right;\"><em>t<\/em><\/td>\n<td style=\"text-align: center;\">=<\/td>\n<td>time (T)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right;\"><em>r<\/em><\/td>\n<td style=\"text-align: center;\">=<\/td>\n<td>radial distance to the observation well (L)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right;\"><em>u<sub>a<\/sub><\/em><\/td>\n<td style=\"text-align: center;\">=<\/td>\n<td>early time values of <em>u<\/em> (dimensionless)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right;\"><em>u<sub>y<\/sub><\/em><\/td>\n<td style=\"text-align: center;\">=<\/td>\n<td>late time values of <em>u<\/em> (dimensionless)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right;\">W(<em>u<sub>a<\/sub><\/em>,<em>u<sub>y<\/sub><\/em>,<em>\u03b7<\/em>)<\/td>\n<td style=\"text-align: center;\">=<\/td>\n<td>unconfined well function (dimensionless)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right;\"><em>K<sub>z<\/sub><\/em><\/td>\n<td style=\"text-align: center;\">=<\/td>\n<td>unconfined vertical hydraulic conductivity (LT<sup>\u20111<\/sup>)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right;\"><em>K<sub>h<\/sub><\/em><\/td>\n<td style=\"text-align: center;\">=<\/td>\n<td>unconfined horizontal hydraulic conductivity (LT<sup>\u20111<\/sup>)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right;\"><em>b<\/em><\/td>\n<td style=\"text-align: center;\">=<\/td>\n<td>pre\u2011pumping saturated thickness (L)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right;\"><em>\u03b7<\/em><\/td>\n<td style=\"text-align: center;\">=<\/td>\n<td>variable defined by Equation\u00a0<a href=\"\/an-introduction-to-hydraulic-testing-in-hydrogeology\/chapter\/formulating-delayed-yield-analysis\/#Xc5aa6d4dcde6806a0ce4e6a17bac04d6b244544\">(73)<\/a> (dimensionless)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div data-custom-style=\"Body Text\">\n<p><strong>Example<\/strong><\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p><em>T<\/em>, <em>S<\/em>, and <em>S<sub>y <\/sub><\/em>can be estimated using the match points (<a href=\"#X414fef407a3e6a68430e2fc1123cf2adc2611f9\">Figure 64<\/a> and <a href=\"#X7329eacce2995531ac62671d0dda138ddc2ec52\">Figure 65<\/a>) if it is assumed that the data represented in <a href=\"#Xcafbbd9ba4c52f7001c9fdaa2ff82a10957f7dc\">Figure 63<\/a> were collected at an observation well located 120 m from the pumping well during a 4\u2011day hydraulic test with a well pumping at 4,000 m<sup>3<\/sup>\/d. The aquifer has a pre\u2011pumping saturated thickness of 28 m and is sand and gravel. Match point data in <a href=\"#X414fef407a3e6a68430e2fc1123cf2adc2611f9\">Figure 64<\/a> are used to compute the transmissivity from early\u2011time data using Equation\u00a0<a href=\"#Xfe7346c9d0a4d2b80f983c4f6dd5ae15cdfa251\">(74)<\/a> and storativity using Equation\u00a0<a href=\"#Xc955a151795a3165fb856990d35d57f607bf50e\">(75)<\/a>.<\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<div class=\"display-math\" data-custom-style=\"Display Equation\">\n<p>[latex]T = \\frac{4000\\frac{m^{3}}{d}}{4\\ (3.14)\\ 1\\ m}\\ (1) = 318\\frac{m^{2}}{d}[\/latex]<\/p>\n<\/div>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<div class=\"display-math\" data-custom-style=\"Display Equation\">\n<p>[latex]S = \\frac{(1)\\ 4\\ \\left( 318\\frac{\\ m^{2}}{d} \\right)0.0005\\ d}{{(120\\ m)}^{2}} = 0.000044\\ \\ or\\ \\ 4.4{x10}^{- 5}[\/latex]<\/p>\n<\/div>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>Using the late time match point of <a href=\"#X7329eacce2995531ac62671d0dda138ddc2ec52\">Figure 65<\/a> and Equations <a href=\"#Xfe7346c9d0a4d2b80f983c4f6dd5ae15cdfa251\">(74)<\/a> and <a href=\"#Xf8359b96e0ffc9e0f8f7cd1c62dd7e2fc5a133e\">(76)<\/a>, transmissivity and specific yield are calculated.<\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<div class=\"display-math\" data-custom-style=\"Display Equation\">\n<p>[latex]T = \\frac{4000\\frac{m^{3}}{d}}{4\\ (3.14)\\ 0.98\\ m}\\ (1) = 325\\frac{m^{2}}{d}[\/latex]<\/p>\n<\/div>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<div class=\"display-math\" data-custom-style=\"Display Equation\">\n<p>[latex]S_{y} = \\frac{(1)\\ 4\\ \\left( 325\\frac{\\ m^{2}}{d} \\right)\\ 0.25\\ d}{{(120\\ m)}^{2}} = 0.02[\/latex]<\/p>\n<\/div>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>Averaging the <em>T<\/em> values yields a value of 322 m<sup>2<\/sup>\/d. In this example the confined storage coefficient seems reasonable, but the specific yield is quite small and most likely not representative of field conditions. This suggests that analytical formulations may not fully capture the release of water as the aquifer dewaters.<\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>The horizontal hydraulic conductivity is computed using Equation\u00a0<a href=\"#X7b78df277ba5e1d2954b8f19d4b1f256cef6e3d\">(77)<\/a><\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<div class=\"display-math\" data-custom-style=\"Display Equation\">\n<p>[latex]\\frac{322\\frac{\\ m^{2}}{d}}{28\\ m} = 11.5\\ \\frac{m}{d}[\/latex]<\/p>\n<\/div>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>Next using Equation\u00a0<a href=\"#X4322394716e08947e156007088e9fb58ac9e453\">(78)<\/a> and match point value of <em>\u03b7<\/em> =2.0, vertical hydraulic conductivity is calculated.<\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<div class=\"display-math\" data-custom-style=\"Display Equation\">\n<p>[latex]K_{z} = \\frac{(1)\\ 2.0\\ {(28\\ m)}^{2}\\ \\ 11.5\\ \\frac{m}{d}}{{(120\\ m)}^{2}} = 1.3\\frac{m}{d}[\/latex]<\/p>\n<\/div>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>Analytical approaches to describing the response of wells when pumping an unconfined system were outlined in this section. Numerical methods can also be used to approximate the response of unconfined aquifers to pumping. However, representation of delayed yield processes requires additional model complexity (e.g., Anderson et al., 2015; Diersch, 2014).<\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>Section\u00a011 presents methods to assess how boundaries, well interference, and anisotropy affect efforts to forecast drawdowns and estimate hydrogeologic properties.<\/p>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"author":8,"menu_order":43,"template":"","meta":{"pb_show_title":"on","pb_short_title":"","pb_subtitle":"","pb_authors":[],"pb_section_license":""},"chapter-type":[],"contributor":[],"license":[],"class_list":["post-1695","chapter","type-chapter","status-publish","hentry"],"part":576,"_links":{"self":[{"href":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-json\/pressbooks\/v2\/chapters\/1695","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-json\/pressbooks\/v2\/chapters"}],"about":[{"href":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-json\/wp\/v2\/types\/chapter"}],"author":[{"embeddable":true,"href":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-json\/wp\/v2\/users\/8"}],"version-history":[{"count":3,"href":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-json\/pressbooks\/v2\/chapters\/1695\/revisions"}],"predecessor-version":[{"id":3300,"href":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-json\/pressbooks\/v2\/chapters\/1695\/revisions\/3300"}],"part":[{"href":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-json\/pressbooks\/v2\/parts\/576"}],"metadata":[{"href":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-json\/pressbooks\/v2\/chapters\/1695\/metadata\/"}],"wp:attachment":[{"href":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-json\/wp\/v2\/media?parent=1695"}],"wp:term":[{"taxonomy":"chapter-type","embeddable":true,"href":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-json\/pressbooks\/v2\/chapter-type?post=1695"},{"taxonomy":"contributor","embeddable":true,"href":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-json\/wp\/v2\/contributor?post=1695"},{"taxonomy":"license","embeddable":true,"href":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-json\/wp\/v2\/license?post=1695"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}