{"id":1795,"date":"2026-02-14T04:27:36","date_gmt":"2026-02-14T04:27:36","guid":{"rendered":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/chapter\/ch075-xhtml\/"},"modified":"2026-08-01T10:00:27","modified_gmt":"2026-08-01T10:00:27","slug":"testing-methods-and-analyses","status":"publish","type":"chapter","link":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/chapter\/testing-methods-and-analyses\/","title":{"raw":"15.2 Testing Methods and Analyses","rendered":"15.2 Testing Methods and Analyses"},"content":{"raw":"<div id=\"testing-methods-and-analyses\" class=\"level1\">\r\n<div data-custom-style=\"First Paragraph\">\r\n<div data-custom-style=\"First Paragraph\">\r\n\r\nPacker testing is most frequently applied to boreholes in rock. Testing methods can also examine bulk properties and properties of individual fractures. The work of Quinn and others (2012) is comprehensive reference on borehole testing in fractured rock and provides details on a versatile straddle\u2011packer system they developed to provide transmissivity estimates. They list four types of hydraulic tests used in porous media that are commonly applied to fractured\u2011rock boreholes. These are also applicable to some screened boreholes in good communication with the undisturbed formation (<a href=\"\/an-introduction-to-hydraulic-testing-in-hydrogeology\/chapter\/the-packer-test\/#Xeb43bea6bfd7cdec35297cbb880f661bcd9c22b\">Figure 133<\/a>). Tests include constant\u2011head step test, instantaneous slug, constant\u2011rate pumping, and recovery after constant\u2011rate pumping. In some settings where groundwater\u2011velocity data are desired, borehole\u2011dilution methods that circulate a tracer in the packed\u2011off section of the borehole are used (e.g., Maldaner et al., 2018). Slug, constant\u2011rate pumping, and constant\u2011head injection\/withdrawal tests are discussed here. Refer to Quinn and others (2012) for application of other methods.\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nThe packer\u2011test records should include a drillers log, borehole configuration, the dimensions of the test interval, top and bottom elevations of the packers, time and water\u2011level change data, and the start and stop times. A transducer system is usually used to monitor heads in the test zone. When data loggers are connected to an onsite recording and visualization system, real\u2011time head changes and flow rates can be observed.\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nPacker\u2011isolated sections of a borehole can be tested using standard slug\u2011test methods described in Section 14, pumping tests for single wells presented in Section 12, and constant\u2011head injection\/withdrawal, step\u2011rate injection, and drill\u2011stem tests described in this section.\r\n\r\n<\/div>\r\n<div id=\"slug-tests-1\" class=\"level3\">\r\n<h3>Slug Tests<\/h3>\r\n<div data-custom-style=\"First Paragraph\">\r\n\r\nA single\u2011 or dual\u2011packer system can be used to isolate a zone of interest such that a rising\u2011 or falling\u2011head slug test can be executed. A transducer located in the packed\u2011off zone is installed and records water\u2011level changes with time. As described in Section 14, the head is instantaneously raised or lowered, and the response of the recovering head is observed. Standard slug\u2011test analysis methods for a given formation type (unconfined or confined) can be used to analyze the data as described in Section 14.\r\n\r\n<\/div>\r\n<\/div>\r\n<div id=\"constantrate-pumping-tests\" class=\"level3\">\r\n<h3>Constant\u2011Rate Pumping Tests<\/h3>\r\n<div data-custom-style=\"First Paragraph\">\r\n\r\nWhen a pump is installed between a double packer or below a single packer, a constant\u2011discharge aquifer test can be conducted, and <em>T<\/em> values can be approximated. As observation wells are rarely used, estimates of <em>S<\/em> are usually poor as explained in Section 12. Transient or steady\u2011state testing can be performed. Most often the test will be conducted and analyzed as a single\u2011well test. Analyses methods have been described previously in Sections 7 through 10 and Section 12.\r\n\r\n<\/div>\r\n<\/div>\r\n<div id=\"constanthead-injectionwithdrawal-test\" class=\"level3\">\r\n<h3>Constant\u2011Head Injection\/Withdrawal Test<\/h3>\r\n<div data-custom-style=\"First Paragraph\">\r\n\r\nThis section describes how a constant\u2011head injection test is performed using a dual\u2011packer system. Lapcevic and others (1999) provide a complete discussion of constant\u2011head testing methods.\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nA constant\u2011head injection\/withdrawal test (also referred to as a Lugeon test or constant\u2011pressure test) injects or withdraws water under a constant head to or from a packed\u2011off test interval until a constant\u2011flow rate is achieved. This simulates steady\u2011state conditions (Ziegler, 1976). To achieve a constant\u2011flow rate at a constant head, water could be pumped into the test interval, however, when permeabilities are low, flow rates may be difficult to maintain. Lapcevic and others (1999) report that more commonly a series of water\u2011filled tanks of varying diameters pressurized with nitrogen are used to maintain constant\u2011 (and sometimes very\u2011low) flow rates (<a href=\"#X47969367424f124f36c0ff8b629376c1a46d290\">Figure 135<\/a>). Manometers are attached to each tank to measure the tank\u2019s level and the constant head is maintained by a control panel. The flow rate is measured by monitoring the rate of change of the manometer level in each tank with the pressure held constant as the tanks empty. Lapcevic and others (1999) report that this set up generates a wide range of flow rates such that zone transmissivities ranging from 1x10<sup>\u201110<\/sup> to 1x10<sup>\u20113<\/sup> m<sup>2<\/sup>\/s can be measured. They recommend that multiple tests should be conducted by increasing the pressure used during each test.\r\n\r\n<\/div>\r\n<div class=\"bc-figure figure\" data-custom-style=\"Captioned Figure\"><img style=\"display: block; margin-left: auto; margin-right: auto; ;width: 5.83333in; height: 4.61806in;\" src=\"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-content\/uploads\/sites\/40\/2026\/08\/file140-2.jpg\" alt=\"\" \/>\r\n<div class=\"bc-figcaption figcaption\">\r\n<div data-custom-style=\"Image Caption\">\r\n<div class=\"figcaption-text\">\r\n\r\n<span id=\"X47969367424f124f36c0ff8b629376c1a46d290\" class=\"anchor\"><strong>Figure 135 \u2011<\/strong> Set\u2011up of a constant\u2011head injection test using multiple tanks to maintain a constant head and flow rate. A constant head is maintained between the packer interval and the pressurized water tanks (\u2206<em>H<\/em>). The dashed cross section of a borehole is displayed with two packers isolating a test zone (<em>b<\/em>). Pressurized nitrogen gas is used to empty the tanks at a constant rate. <em>r<sub>w<\/sub><\/em> is the radius of the borehole and <em>r<sub>e<\/sub><\/em> is the radius of influence of the test (modified from Lapcevic et al., 1999).<\/span>\r\n\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nAnalyzing Injection\/Withdrawal Test Results\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nThe constant\u2011head injection\/withdrawal test is run until the flow rate is no longer changing. The interval transmissivity can be estimated using the Thiem equation for a confined system as shown in Equation\u00a0<a href=\"#Xb416d755f0c3fc1f71df1ac4b90257a0abd04dc\">(124)<\/a>. It is assumed that purely radial flow is occurring from the packed off interval.\r\n\r\n<\/div>\r\n<table class=\"gw-eq-table\" style=\"width: 100%;\" data-custom-style=\"Table\"><colgroup> <col style=\"width: 10%;\" \/> <col style=\"width: 75%;\" \/> <col style=\"width: 15%;\" \/><\/colgroup>\r\n<tbody>\r\n<tr>\r\n<th><\/th>\r\n<th style=\"text-align: center;\">[latex]T = \\frac{Q}{2\\ \\pi\\ \\mathrm{\\Delta}H\\ }\\ln\\left( \\frac{r_{e}}{r_{w}} \\right)[\/latex]<\/th>\r\n<th style=\"text-align: right; white-space: nowrap;\"><span id=\"Xb416d755f0c3fc1f71df1ac4b90257a0abd04dc\" class=\"anchor\">(124)<\/span><\/th>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nwhere:\r\n\r\n<\/div>\r\n<table style=\"width: 85%;\" data-custom-style=\"Table\"><colgroup> <col style=\"width: 14%;\" \/> <col style=\"width: 2%;\" \/> <col style=\"width: 68%;\" \/> <\/colgroup>\r\n<thead>\r\n<tr>\r\n<th style=\"text-align: right;\"><em>T<\/em><\/th>\r\n<th style=\"text-align: left;\">=<\/th>\r\n<th>transmissivity (<em>Kb<\/em> where <em>b<\/em> is the interval thickness) (L<sup>2<\/sup>T<sup>\u20111<\/sup>)<\/th>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr>\r\n<td style=\"text-align: right;\"><em>Q<\/em><\/td>\r\n<td style=\"text-align: left;\">=<\/td>\r\n<td>constant discharge (L<sup>3<\/sup>T<sup>\u20111<\/sup>)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"text-align: right;\">\u2206<em>H<\/em><\/td>\r\n<td style=\"text-align: left;\">=<\/td>\r\n<td>difference in hydraulic head (L)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"text-align: right;\"><em>r<sub>e<\/sub><\/em><\/td>\r\n<td style=\"text-align: left;\">=<\/td>\r\n<td>radius of influence (L)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"text-align: right;\"><em>r<sub>w<\/sub><\/em><\/td>\r\n<td style=\"text-align: left;\">=<\/td>\r\n<td>radius of the borehole (L)<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nThe radius of influence is the extent that injection test affects conditions in the material surrounding the test zone. Lapcevic and others (1999) note that <em>r<sub>e<\/sub><\/em> is often assumed to be 10 to 15 m (Bliss &amp; Ruston, 1984). The <em>T<\/em> calculation is not very sensitive to <em>r<sub>e<\/sub><\/em> as shown by Equation\u00a0<a href=\"#Xb416d755f0c3fc1f71df1ac4b90257a0abd04dc\">(124)<\/a> where <em>r<sub>e<\/sub><\/em> is divided by <em>r<sub>w<\/sub><\/em> and then the natural log of this ratio is computed (Doe &amp; Remer, 1980).\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\n<strong>Example<\/strong>\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nA 4\u2011m section (<em>b<\/em>) of a 0.1\u2011m diameter borehole in a fractured sandstone is isolated by a straddle\u2011packer system (two packers). An injection test is conducted where the head difference is 5 m, and the steady\u2011state flow rate is 1 m<sup>3<\/sup>\/d. The transmissivity (<em>Kb<\/em>) of the test zone is computed using Equation\u00a0<a href=\"#Xb416d755f0c3fc1f71df1ac4b90257a0abd04dc\">(124)<\/a>. The radius of influence (<em>r<sub>e<\/sub><\/em>) is assumed to be 12 m.\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n<div class=\"display-math\" data-custom-style=\"Display Equation\">\r\n\r\n[latex]T = \\frac{Q}{2\\ \\pi\\ \\mathrm{\\Delta}H\\ }\\ln\\left( \\frac{r_{e}}{r_{w}} \\right) = \\frac{1\\frac{m^{3}}{d}}{2\\ (3.14)\\ 5\\ m\\ }\\ln\\left( \\frac{12\\ m}{0.05\\ m} \\right) = 0.174\\frac{m^{2}}{d}[\/latex]\r\n\r\n<\/div>\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nThe horizontal hydraulic conductivity is then equal to T\/b = 0.174 m<sup>2<\/sup>\/d\/4m = 0.044 m\/d. Zones with individual or several fractures can be represented as an equivalent single fracture using an equivalent individual fracture aperture, 2<em>b<sub>eq<\/sub><\/em>. This can be computed from the zone <em>T<\/em> value (Equation\u00a0<a href=\"#Xb416d755f0c3fc1f71df1ac4b90257a0abd04dc\">(124)<\/a>) by applying the cubic law (e.g., Lapcevic et al., 1999) as shown in Equation\u00a0<a href=\"#Xf921b14efd78bb20086945b28fe8e2d949fff93\">(125)<\/a>.\r\n\r\n<\/div>\r\n<table class=\"gw-eq-table\" style=\"width: 100%;\" data-custom-style=\"Table\"><colgroup> <col style=\"width: 10%;\" \/> <col style=\"width: 75%;\" \/> <col style=\"width: 15%;\" \/><\/colgroup>\r\n<tbody>\r\n<tr>\r\n<th><\/th>\r\n<th style=\"text-align: center;\">[latex]2b_{eq} = \\left( \\frac{T12\\mu}{\\gamma} \\right)0.33[\/latex]<\/th>\r\n<th style=\"text-align: right; white-space: nowrap;\"><span id=\"Xf921b14efd78bb20086945b28fe8e2d949fff93\" class=\"anchor\">(125)<\/span><\/th>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nwhere:\r\n\r\n<\/div>\r\n<table style=\"width: 85%;\" data-custom-style=\"Table\"><colgroup> <col style=\"width: 14%;\" \/> <col style=\"width: 2%;\" \/> <col style=\"width: 68%;\" \/> <\/colgroup>\r\n<thead>\r\n<tr>\r\n<th style=\"text-align: right;\">2<em>b<sub>eq <\/sub><\/em><\/th>\r\n<th style=\"text-align: left;\">=<\/th>\r\n<th>equivalent fracture aperture (L)<\/th>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr>\r\n<td style=\"text-align: right;\"><em>T<\/em><\/td>\r\n<td style=\"text-align: left;\">=<\/td>\r\n<td>transmissivity (L<sup>2<\/sup>T<sup>\u20111<\/sup>)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"text-align: right;\"><em>\u03bc<\/em><\/td>\r\n<td style=\"text-align: left;\">=<\/td>\r\n<td>viscosity of water (MTL<sup>\u20111<\/sup>)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"text-align: right;\"><em>\u03b3<\/em><\/td>\r\n<td style=\"text-align: left;\">=<\/td>\r\n<td>specific weight of water (MT<sup>2<\/sup>L<sup>\u20112<\/sup>)<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<\/div>\r\n<div id=\"steprate-injection-test-lugeon-test\" class=\"level3\">\r\n<h3>Step\u2011Rate Injection Test (Lugeon Test)<\/h3>\r\n<div data-custom-style=\"First Paragraph\">\r\n\r\nLugeon tests are commonly performed in geotechnical or underground\u2011mining applications to estimate the hydraulic conductivity and flow regime of a specific test interval. The test method was pioneered by Maurice Lugeon (1933) and later described by Houlsby (1976). It is based on observing the response of the test zone to inflow rate of injected water as the water pressure in the zone increases and decreases. The test set up is presented in <a href=\"#X318416bb7c82224fe571d518ff42046659d82b7\">Figure 136<\/a>.\r\n\r\n<\/div>\r\n<div class=\"bc-figure figure\" data-custom-style=\"Captioned Figure\"><img style=\"display: block; margin-left: auto; margin-right: auto; ;width: 5.83333in; height: 4.67199in;\" src=\"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-content\/uploads\/sites\/40\/2026\/08\/file141-2.jpg\" alt=\"\" \/>\r\n<div class=\"bc-figcaption figcaption\">\r\n<div data-custom-style=\"Image Caption\">\r\n<div class=\"figcaption-text\">\r\n\r\n<span id=\"X318416bb7c82224fe571d518ff42046659d82b7\" class=\"anchor\"><strong>Figure 136 \u2011<\/strong> Schematic set up of a Lugeon test. A dual\u2011packer system inflated with gas isolates the test zone. The injection test uses water from a reservoir and a pump to pressurize the system and inject water into the test zone. The data collected are the inflow rate at a given pressure over time after rate stabilization. The maximum pressure, P<sub>max<\/sub>, is computed based on the thickness of overburden overlying the test interval multiplied by 1 pound per square inch per foot (2.26x10<sup>4<\/sup> pascals\/m). Flow rates at pressures of 50, 75 and 100 percent of P<sub>max<\/sub> are determined and applied during the test; then the pressures are sequentially lowered back to 50 percent and flow rates recorded again for each interval.<\/span>\r\n\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nThe test is conducted using five stages of water pressure injection. Steps 1 through 3 increase pressure while steps 4 and 5 duplicate the pressure of steps 2 and 1, respectively. The five\u2011step pressure 'loop' allows for interpretation of the flow regime and aids in selection of the most representative hydraulic conductivity value (Qui\u00f1ones\u2011Rozo, 2010).\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nThe maximum injection pressure (<em>P<sub>max<\/sub><\/em>) is determined prior to starting the test. <em>P<sub>max<\/sub><\/em> must not exceed the confinement stress in the test interval to avoid hydraulic fracturing. <em>P<sub>max<\/sub><\/em> is typically estimated at 1 pound per square inch (psi) per foot of overburden above the test interval (6,895 Pascal = 1 psi). For example, a <em>P<sub>max<\/sub><\/em> of 200 psi (1.38 MPa) would be appropriate for a test interval located from 61 to 67 m (200 to 220 ft) below ground surface. The vertical thickness of overburden above the test interval is used to calculate <em>P<sub>max<\/sub><\/em> in an angled borehole or for a test conducted beneath a sloping terrain. <em>P<sub>max<\/sub><\/em> represents the highest injection pressure (step 3) and steps 1, 2, 4, and 5 represent multiples of <em>P<sub>max<\/sub><\/em> as shown in <a href=\"#X5fb289fc2a048d1e1fb7f46b54557e8be5805e1\">Figure 137<\/a> (Qui\u00f1ones\u2011Rozo, 2010).\r\n\r\n<\/div>\r\n<div class=\"bc-figure figure\" data-custom-style=\"Captioned Figure\"><img style=\"display: block; margin-left: auto; margin-right: auto; ;width: 5.83333in; height: 3.06464in;\" src=\"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-content\/uploads\/sites\/40\/2026\/08\/file142-2.jpg\" alt=\"\" \/>\r\n<div class=\"bc-figcaption figcaption\">\r\n<div data-custom-style=\"Image Caption\">\r\n<div class=\"figcaption-text\">\r\n\r\n<span id=\"X5fb289fc2a048d1e1fb7f46b54557e8be5805e1\" class=\"anchor\"><strong>Figure 137 \u2011<\/strong> Five pressure steps used in a Lugeon test. <em>P<sub>max<\/sub><\/em> is the maximum pressure computed as 1 psi per foot of overburden above the test zone (2.26x10<sup>4<\/sup> pascals per meter of overburden above the test zone). After step rates have stabilized, the total flow rate is measured every minute over a 10 min interval and the flow rate is determined by averaging the values (Qui\u00f1ones\u2011Rozo, 2010).<\/span>\r\n\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nWater pressure and flow rate are recorded during each step of the test using a totalizing flowmeter, pressure gage\/sensor, and timer. A purge valve on the injection system is used to vent excess pressure from the injection pump which controls the injection pressure into the test interval (<a href=\"#X47969367424f124f36c0ff8b629376c1a46d290\">Figure 135<\/a>). After establishing a constant\u2011flow rate, each stage is typically run for 10 minutes. Pressure and totalizing flowmeter readings are recorded each minute, and the total 'take' (inflow volume) of the test interval is calculated in liters for each step. The average flow rate is computed from the step data. A hydraulic conductivity value is calculated for each step, expressed as an empirical Lugeon value, which is defined as the hydraulic conductivity required to achieve a flow rate of 1 liter per minute per meter of test interval under a reference water pressure equal to 1 MPa.\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nLugeon tests are analyzed based on the total injection pressure and flow during a given step. One Lugeon is equivalent to 1.3 x 10<sup>\u20115<\/sup> centimeters per second under homogenous and isotropic conditions (Qui\u00f1ones\u2011Rozo, 2010). Separate Lugeon values are calculated for each step using Equation\u00a0<a href=\"#X0529a98ed096d2b66774b404eedb78843a988f4\">(126)<\/a>.\r\n\r\n<\/div>\r\n<table class=\"gw-eq-table\" style=\"width: 100%;\" data-custom-style=\"Table\"><colgroup> <col style=\"width: 10%;\" \/> <col style=\"width: 75%;\" \/> <col style=\"width: 15%;\" \/><\/colgroup>\r\n<tbody>\r\n<tr>\r\n<th><\/th>\r\n<th style=\"text-align: center;\">[latex]Lugeon\\ Value = \\ \\alpha\\ \\frac{q}{L}\\ \\frac{P_{0}}{P}[\/latex]<\/th>\r\n<th style=\"text-align: right; white-space: nowrap;\"><span id=\"X0529a98ed096d2b66774b404eedb78843a988f4\" class=\"anchor\">(126)<\/span><\/th>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nwhere:\r\n\r\n<\/div>\r\n<table style=\"width: 85%;\" data-custom-style=\"Table\"><colgroup> <col style=\"width: 14%;\" \/> <col style=\"width: 2%;\" \/> <col style=\"width: 68%;\" \/> <\/colgroup>\r\n<thead>\r\n<tr>\r\n<th style=\"text-align: right;\"><em>Lugeon<\/em><\/th>\r\n<th style=\"text-align: left;\">=<\/th>\r\n<th>reflects hydraulic conductivity of 1.3 x 10<sup>\u20115<\/sup> centimeters per second when determined under homogenous, isotropic conditions<\/th>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr>\r\n<td style=\"text-align: right;\"><em>\u03b1<\/em><\/td>\r\n<td style=\"text-align: left;\">=<\/td>\r\n<td>dimensionless unit\u2011conversion factor (1 for SI units which would be in liters per minute, meters, and megapascals)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"text-align: right;\"><em>q<\/em><\/td>\r\n<td style=\"text-align: left;\">=<\/td>\r\n<td>average flow rate from a single step (in liters per minute)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"text-align: right;\"><em>L<\/em><\/td>\r\n<td style=\"text-align: left;\">=<\/td>\r\n<td>length of test interval (in meters)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"text-align: right;\"><em>P<sub>0<\/sub><\/em><\/td>\r\n<td style=\"text-align: left;\">=<\/td>\r\n<td>reference pressure, which is defined as 1 megapascal<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"text-align: right;\"><em>P<\/em><\/td>\r\n<td style=\"text-align: left;\">=<\/td>\r\n<td>total pressure head above static pressure (i.e., injection pressure + pressure head + frictional losses)<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nHoulsby (1976) developed a method to select a representative Lugeon value or equivalent hydraulic conductivity to represent the test interval using the observed patterns of Lugeon values. His method uses a bar graph of Lugeon values calculated for each step. The test values are matched to a pattern, and a method to generate a representative hydraulic conductivity value is selected. The patterns are labeled as representing flow regimes that include (1) laminar flow, (2) turbulent flow, (3) dilation, (4) wash\u2011out, or (5) void filling. Each regime is described in the caption of <a href=\"#X9e3a48cff505f46a8ba070f4ebe2edc3b03da47\">Figure 138<\/a>.\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\n<img style=\"display: block; margin-left: auto; margin-right: auto; ;width: 5.83333in; height: 6.90877in;\" src=\"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-content\/uploads\/sites\/40\/2026\/08\/file143-2.jpg\" alt=\"\" \/>\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n<div class=\"figcaption-text\">\r\n\r\n<span id=\"X9e3a48cff505f46a8ba070f4ebe2edc3b03da47\" class=\"anchor\"><strong>Figure 138 \u2011\u00a0<\/strong>Lugeon\u2011test patterns and flow\u2011regime interpretation (Houlsby, 1976). The pressure stages are the same for each Lugeon pattern. However, the calculation of a representative hydraulic conductivity value is dependent on the pattern of test Lugeon values. (1) Laminar Flow \u2013 All Lugeon values for each step are similar, therefore laminar flow is occurring. The representative value is the average of all five steps. (2) Turbulent flow \u2013 The lowest Lugeon value occurs at the highest pressure, therefore turbulent flow is occurring. The representative value is the Lugeon value for the highest pressure. (3) Dilation \u2013 The highest Lugeon value occurs at the highest pressure, therefore fracture dilation is occurring at high pressure. The representative value is the average of the low pressure (1,5) or medium pressure (2,4) steps. (4) Wash\u2011Out \u2013 Lugeon values increase with each step regardless of pressure, therefore gouge or weathered minerals are washing out of fractures. The representative Lugeon value is the highest observed value unless special conditions dictate otherwise. (5) Void Filling \u2013 Lugeon Values decrease with each step regardless of pressure, therefore gouge or weathered minerals are filling in small aperture fractures. The representative value is the Lugeon value for the lowest pressure.<\/span>\r\n\r\n<\/div>\r\n<\/div>\r\n<div data-custom-style=\"Block Text\">\r\n<blockquote><strong>Example<\/strong><\/blockquote>\r\n<\/div>\r\n<div data-custom-style=\"First Paragraph\">\r\n\r\nA 11.6\u2011m long test section of borehole in a fractured sandstone is isolated by a straddle\u2011packer system (two packers). The first Lugeon test step is conducted for 10 minutes, has an average total head pressure above static of 0.084 megapascals (MPa) and the formation takes a total of 390 liters throughout the step. Using Equation\u00a0<a href=\"#X0529a98ed096d2b66774b404eedb78843a988f4\">(126)<\/a> with an SI unit conversion factor of one, a total head of 0.084 MPa, and an average flow rate of 39 liters per minute yields 40 Lugeons.\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n<div class=\"display-math\" data-custom-style=\"Display Equation\">\r\n\r\n[latex]Lugeon\\ Value = \\alpha\\ \\frac{q}{L}\\ \\frac{P_{0}}{P} = \\ 1\\ \\frac{39\\frac{L}{\\min}}{11.6\\ m}\\ \\frac{1\\ MPa}{0.084\\ MPa} = 40\\ Lugeons[\/latex]\r\n\r\n<\/div>\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nA Lugeon value of 40 is approximately 5.2 x 10<sup>\u20114<\/sup> cm\/s. As indicated in the parameter definitions for Equation\u00a0<a href=\"#X0529a98ed096d2b66774b404eedb78843a988f4\">(126)<\/a>, one Lugeon value is equivalent to 1.3 x 10<sup>\u20115<\/sup> centimeters per second under homogenous and isotropic conditions (Qui\u00f1ones\u2011Rozo 2010).\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nThe software program AquiferTest V12 provides methods to interpret Lugeon\u2011test results. The user\u2019s manual provides details on methods and data requirements (Waterloo Hydrogeologic, 2021).\r\n\r\n<\/div>\r\n<\/div>\r\n<div id=\"drillstem-test\" class=\"level3\">\r\n<h3>Drill\u2011Stem Test<\/h3>\r\n<div data-custom-style=\"First Paragraph\">\r\n\r\nEstimates of horizontal hydraulic conductivity using a packed\u2011off interval of a borehole have been of interest to the petroleum industry for many years (e.g., Mathews &amp; Russel, 1967; Earlougher, 1977). The drill\u2011stem test procedure is also applicable to the characterization of some confined hydrogeologic settings.\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nConceptually, a drill\u2011stem test involves outfitting the drill stem with a test apparatus within the interval of interest that has packers, valves, and pressure\u2011monitoring systems. The packer system is used to isolate a section of borehole. Valves are opened at the start of the test and fluid from the packer zone flows into the drill stem for a period of time. Then the valve is closed. The pressure system monitors the starting formational pressures and the recovery pressures after the value is closed. A discharge rate is computed from the rate that the volume of water fills the drill stem once the test is initiated. Analyses of the data are achieved by using recovery theory once the valve system is closed. Domenico and Schwartz (1998) have a brief discussion of the method and data analysis. Additional, detail and methods are found on sites like <a href=\"https:\/\/wiki.aapg.org\/Drill_stem_testing\">wiki.aapg.org\/Drill_stem_testing<\/a>\u2197 and in the literature.\r\n\r\n<\/div>\r\n<div data-custom-style=\"Body Text\">\r\n\r\nSection 16 addresses hydraulic testing to characterize low\u2011permeability units such as confining units or aquitards.\r\n\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>","rendered":"<div id=\"testing-methods-and-analyses\" class=\"level1\">\n<div data-custom-style=\"First Paragraph\">\n<div data-custom-style=\"First Paragraph\">\n<p>Packer testing is most frequently applied to boreholes in rock. Testing methods can also examine bulk properties and properties of individual fractures. The work of Quinn and others (2012) is comprehensive reference on borehole testing in fractured rock and provides details on a versatile straddle\u2011packer system they developed to provide transmissivity estimates. They list four types of hydraulic tests used in porous media that are commonly applied to fractured\u2011rock boreholes. These are also applicable to some screened boreholes in good communication with the undisturbed formation (<a href=\"\/an-introduction-to-hydraulic-testing-in-hydrogeology\/chapter\/the-packer-test\/#Xeb43bea6bfd7cdec35297cbb880f661bcd9c22b\">Figure 133<\/a>). Tests include constant\u2011head step test, instantaneous slug, constant\u2011rate pumping, and recovery after constant\u2011rate pumping. In some settings where groundwater\u2011velocity data are desired, borehole\u2011dilution methods that circulate a tracer in the packed\u2011off section of the borehole are used (e.g., Maldaner et al., 2018). Slug, constant\u2011rate pumping, and constant\u2011head injection\/withdrawal tests are discussed here. Refer to Quinn and others (2012) for application of other methods.<\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>The packer\u2011test records should include a drillers log, borehole configuration, the dimensions of the test interval, top and bottom elevations of the packers, time and water\u2011level change data, and the start and stop times. A transducer system is usually used to monitor heads in the test zone. When data loggers are connected to an onsite recording and visualization system, real\u2011time head changes and flow rates can be observed.<\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>Packer\u2011isolated sections of a borehole can be tested using standard slug\u2011test methods described in Section 14, pumping tests for single wells presented in Section 12, and constant\u2011head injection\/withdrawal, step\u2011rate injection, and drill\u2011stem tests described in this section.<\/p>\n<\/div>\n<div id=\"slug-tests-1\" class=\"level3\">\n<h3>Slug Tests<\/h3>\n<div data-custom-style=\"First Paragraph\">\n<p>A single\u2011 or dual\u2011packer system can be used to isolate a zone of interest such that a rising\u2011 or falling\u2011head slug test can be executed. A transducer located in the packed\u2011off zone is installed and records water\u2011level changes with time. As described in Section 14, the head is instantaneously raised or lowered, and the response of the recovering head is observed. Standard slug\u2011test analysis methods for a given formation type (unconfined or confined) can be used to analyze the data as described in Section 14.<\/p>\n<\/div>\n<\/div>\n<div id=\"constantrate-pumping-tests\" class=\"level3\">\n<h3>Constant\u2011Rate Pumping Tests<\/h3>\n<div data-custom-style=\"First Paragraph\">\n<p>When a pump is installed between a double packer or below a single packer, a constant\u2011discharge aquifer test can be conducted, and <em>T<\/em> values can be approximated. As observation wells are rarely used, estimates of <em>S<\/em> are usually poor as explained in Section 12. Transient or steady\u2011state testing can be performed. Most often the test will be conducted and analyzed as a single\u2011well test. Analyses methods have been described previously in Sections 7 through 10 and Section 12.<\/p>\n<\/div>\n<\/div>\n<div id=\"constanthead-injectionwithdrawal-test\" class=\"level3\">\n<h3>Constant\u2011Head Injection\/Withdrawal Test<\/h3>\n<div data-custom-style=\"First Paragraph\">\n<p>This section describes how a constant\u2011head injection test is performed using a dual\u2011packer system. Lapcevic and others (1999) provide a complete discussion of constant\u2011head testing methods.<\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>A constant\u2011head injection\/withdrawal test (also referred to as a Lugeon test or constant\u2011pressure test) injects or withdraws water under a constant head to or from a packed\u2011off test interval until a constant\u2011flow rate is achieved. This simulates steady\u2011state conditions (Ziegler, 1976). To achieve a constant\u2011flow rate at a constant head, water could be pumped into the test interval, however, when permeabilities are low, flow rates may be difficult to maintain. Lapcevic and others (1999) report that more commonly a series of water\u2011filled tanks of varying diameters pressurized with nitrogen are used to maintain constant\u2011 (and sometimes very\u2011low) flow rates (<a href=\"#X47969367424f124f36c0ff8b629376c1a46d290\">Figure 135<\/a>). Manometers are attached to each tank to measure the tank\u2019s level and the constant head is maintained by a control panel. The flow rate is measured by monitoring the rate of change of the manometer level in each tank with the pressure held constant as the tanks empty. Lapcevic and others (1999) report that this set up generates a wide range of flow rates such that zone transmissivities ranging from 1&#215;10<sup>\u201110<\/sup> to 1&#215;10<sup>\u20113<\/sup> m<sup>2<\/sup>\/s can be measured. They recommend that multiple tests should be conducted by increasing the pressure used during each test.<\/p>\n<\/div>\n<div class=\"bc-figure figure\" data-custom-style=\"Captioned Figure\"><img decoding=\"async\" style=\"display: block; margin-left: auto; margin-right: auto; ;width: 5.83333in; height: 4.61806in;\" src=\"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-content\/uploads\/sites\/40\/2026\/08\/file140-2.jpg\" alt=\"\" \/><\/p>\n<div class=\"bc-figcaption figcaption\">\n<div data-custom-style=\"Image Caption\">\n<div class=\"figcaption-text\">\n<p><span id=\"X47969367424f124f36c0ff8b629376c1a46d290\" class=\"anchor\"><strong>Figure 135 \u2011<\/strong> Set\u2011up of a constant\u2011head injection test using multiple tanks to maintain a constant head and flow rate. A constant head is maintained between the packer interval and the pressurized water tanks (\u2206<em>H<\/em>). The dashed cross section of a borehole is displayed with two packers isolating a test zone (<em>b<\/em>). Pressurized nitrogen gas is used to empty the tanks at a constant rate. <em>r<sub>w<\/sub><\/em> is the radius of the borehole and <em>r<sub>e<\/sub><\/em> is the radius of influence of the test (modified from Lapcevic et al., 1999).<\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>Analyzing Injection\/Withdrawal Test Results<\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>The constant\u2011head injection\/withdrawal test is run until the flow rate is no longer changing. The interval transmissivity can be estimated using the Thiem equation for a confined system as shown in Equation\u00a0<a href=\"#Xb416d755f0c3fc1f71df1ac4b90257a0abd04dc\">(124)<\/a>. It is assumed that purely radial flow is occurring from the packed off interval.<\/p>\n<\/div>\n<table class=\"gw-eq-table\" style=\"width: 100%;\" data-custom-style=\"Table\">\n<colgroup>\n<col style=\"width: 10%;\" \/>\n<col style=\"width: 75%;\" \/>\n<col style=\"width: 15%;\" \/><\/colgroup>\n<tbody>\n<tr>\n<th><\/th>\n<th style=\"text-align: center;\">[latex]T = \\frac{Q}{2\\ \\pi\\ \\mathrm{\\Delta}H\\ }\\ln\\left( \\frac{r_{e}}{r_{w}} \\right)[\/latex]<\/th>\n<th style=\"text-align: right; white-space: nowrap;\"><span id=\"Xb416d755f0c3fc1f71df1ac4b90257a0abd04dc\" class=\"anchor\">(124)<\/span><\/th>\n<\/tr>\n<\/tbody>\n<\/table>\n<div data-custom-style=\"Body Text\">\n<p>where:<\/p>\n<\/div>\n<table style=\"width: 85%;\" data-custom-style=\"Table\">\n<colgroup>\n<col style=\"width: 14%;\" \/>\n<col style=\"width: 2%;\" \/>\n<col style=\"width: 68%;\" \/> <\/colgroup>\n<thead>\n<tr>\n<th style=\"text-align: right;\"><em>T<\/em><\/th>\n<th style=\"text-align: left;\">=<\/th>\n<th>transmissivity (<em>Kb<\/em> where <em>b<\/em> is the interval thickness) (L<sup>2<\/sup>T<sup>\u20111<\/sup>)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: right;\"><em>Q<\/em><\/td>\n<td style=\"text-align: left;\">=<\/td>\n<td>constant discharge (L<sup>3<\/sup>T<sup>\u20111<\/sup>)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right;\">\u2206<em>H<\/em><\/td>\n<td style=\"text-align: left;\">=<\/td>\n<td>difference in hydraulic head (L)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right;\"><em>r<sub>e<\/sub><\/em><\/td>\n<td style=\"text-align: left;\">=<\/td>\n<td>radius of influence (L)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right;\"><em>r<sub>w<\/sub><\/em><\/td>\n<td style=\"text-align: left;\">=<\/td>\n<td>radius of the borehole (L)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div data-custom-style=\"Body Text\">\n<p>The radius of influence is the extent that injection test affects conditions in the material surrounding the test zone. Lapcevic and others (1999) note that <em>r<sub>e<\/sub><\/em> is often assumed to be 10 to 15 m (Bliss &amp; Ruston, 1984). The <em>T<\/em> calculation is not very sensitive to <em>r<sub>e<\/sub><\/em> as shown by Equation\u00a0<a href=\"#Xb416d755f0c3fc1f71df1ac4b90257a0abd04dc\">(124)<\/a> where <em>r<sub>e<\/sub><\/em> is divided by <em>r<sub>w<\/sub><\/em> and then the natural log of this ratio is computed (Doe &amp; Remer, 1980).<\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p><strong>Example<\/strong><\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>A 4\u2011m section (<em>b<\/em>) of a 0.1\u2011m diameter borehole in a fractured sandstone is isolated by a straddle\u2011packer system (two packers). An injection test is conducted where the head difference is 5 m, and the steady\u2011state flow rate is 1 m<sup>3<\/sup>\/d. The transmissivity (<em>Kb<\/em>) of the test zone is computed using Equation\u00a0<a href=\"#Xb416d755f0c3fc1f71df1ac4b90257a0abd04dc\">(124)<\/a>. The radius of influence (<em>r<sub>e<\/sub><\/em>) is assumed to be 12 m.<\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<div class=\"display-math\" data-custom-style=\"Display Equation\">\n<p>[latex]T = \\frac{Q}{2\\ \\pi\\ \\mathrm{\\Delta}H\\ }\\ln\\left( \\frac{r_{e}}{r_{w}} \\right) = \\frac{1\\frac{m^{3}}{d}}{2\\ (3.14)\\ 5\\ m\\ }\\ln\\left( \\frac{12\\ m}{0.05\\ m} \\right) = 0.174\\frac{m^{2}}{d}[\/latex]<\/p>\n<\/div>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>The horizontal hydraulic conductivity is then equal to T\/b = 0.174 m<sup>2<\/sup>\/d\/4m = 0.044 m\/d. Zones with individual or several fractures can be represented as an equivalent single fracture using an equivalent individual fracture aperture, 2<em>b<sub>eq<\/sub><\/em>. This can be computed from the zone <em>T<\/em> value (Equation\u00a0<a href=\"#Xb416d755f0c3fc1f71df1ac4b90257a0abd04dc\">(124)<\/a>) by applying the cubic law (e.g., Lapcevic et al., 1999) as shown in Equation\u00a0<a href=\"#Xf921b14efd78bb20086945b28fe8e2d949fff93\">(125)<\/a>.<\/p>\n<\/div>\n<table class=\"gw-eq-table\" style=\"width: 100%;\" data-custom-style=\"Table\">\n<colgroup>\n<col style=\"width: 10%;\" \/>\n<col style=\"width: 75%;\" \/>\n<col style=\"width: 15%;\" \/><\/colgroup>\n<tbody>\n<tr>\n<th><\/th>\n<th style=\"text-align: center;\">[latex]2b_{eq} = \\left( \\frac{T12\\mu}{\\gamma} \\right)0.33[\/latex]<\/th>\n<th style=\"text-align: right; white-space: nowrap;\"><span id=\"Xf921b14efd78bb20086945b28fe8e2d949fff93\" class=\"anchor\">(125)<\/span><\/th>\n<\/tr>\n<\/tbody>\n<\/table>\n<div data-custom-style=\"Body Text\">\n<p>where:<\/p>\n<\/div>\n<table style=\"width: 85%;\" data-custom-style=\"Table\">\n<colgroup>\n<col style=\"width: 14%;\" \/>\n<col style=\"width: 2%;\" \/>\n<col style=\"width: 68%;\" \/> <\/colgroup>\n<thead>\n<tr>\n<th style=\"text-align: right;\">2<em>b<sub>eq <\/sub><\/em><\/th>\n<th style=\"text-align: left;\">=<\/th>\n<th>equivalent fracture aperture (L)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: right;\"><em>T<\/em><\/td>\n<td style=\"text-align: left;\">=<\/td>\n<td>transmissivity (L<sup>2<\/sup>T<sup>\u20111<\/sup>)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right;\"><em>\u03bc<\/em><\/td>\n<td style=\"text-align: left;\">=<\/td>\n<td>viscosity of water (MTL<sup>\u20111<\/sup>)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right;\"><em>\u03b3<\/em><\/td>\n<td style=\"text-align: left;\">=<\/td>\n<td>specific weight of water (MT<sup>2<\/sup>L<sup>\u20112<\/sup>)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div id=\"steprate-injection-test-lugeon-test\" class=\"level3\">\n<h3>Step\u2011Rate Injection Test (Lugeon Test)<\/h3>\n<div data-custom-style=\"First Paragraph\">\n<p>Lugeon tests are commonly performed in geotechnical or underground\u2011mining applications to estimate the hydraulic conductivity and flow regime of a specific test interval. The test method was pioneered by Maurice Lugeon (1933) and later described by Houlsby (1976). It is based on observing the response of the test zone to inflow rate of injected water as the water pressure in the zone increases and decreases. The test set up is presented in <a href=\"#X318416bb7c82224fe571d518ff42046659d82b7\">Figure 136<\/a>.<\/p>\n<\/div>\n<div class=\"bc-figure figure\" data-custom-style=\"Captioned Figure\"><img decoding=\"async\" style=\"display: block; margin-left: auto; margin-right: auto; ;width: 5.83333in; height: 4.67199in;\" src=\"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-content\/uploads\/sites\/40\/2026\/08\/file141-2.jpg\" alt=\"\" \/><\/p>\n<div class=\"bc-figcaption figcaption\">\n<div data-custom-style=\"Image Caption\">\n<div class=\"figcaption-text\">\n<p><span id=\"X318416bb7c82224fe571d518ff42046659d82b7\" class=\"anchor\"><strong>Figure 136 \u2011<\/strong> Schematic set up of a Lugeon test. A dual\u2011packer system inflated with gas isolates the test zone. The injection test uses water from a reservoir and a pump to pressurize the system and inject water into the test zone. The data collected are the inflow rate at a given pressure over time after rate stabilization. The maximum pressure, P<sub>max<\/sub>, is computed based on the thickness of overburden overlying the test interval multiplied by 1 pound per square inch per foot (2.26&#215;10<sup>4<\/sup> pascals\/m). Flow rates at pressures of 50, 75 and 100 percent of P<sub>max<\/sub> are determined and applied during the test; then the pressures are sequentially lowered back to 50 percent and flow rates recorded again for each interval.<\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>The test is conducted using five stages of water pressure injection. Steps 1 through 3 increase pressure while steps 4 and 5 duplicate the pressure of steps 2 and 1, respectively. The five\u2011step pressure &#8216;loop&#8217; allows for interpretation of the flow regime and aids in selection of the most representative hydraulic conductivity value (Qui\u00f1ones\u2011Rozo, 2010).<\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>The maximum injection pressure (<em>P<sub>max<\/sub><\/em>) is determined prior to starting the test. <em>P<sub>max<\/sub><\/em> must not exceed the confinement stress in the test interval to avoid hydraulic fracturing. <em>P<sub>max<\/sub><\/em> is typically estimated at 1 pound per square inch (psi) per foot of overburden above the test interval (6,895 Pascal = 1 psi). For example, a <em>P<sub>max<\/sub><\/em> of 200 psi (1.38 MPa) would be appropriate for a test interval located from 61 to 67 m (200 to 220 ft) below ground surface. The vertical thickness of overburden above the test interval is used to calculate <em>P<sub>max<\/sub><\/em> in an angled borehole or for a test conducted beneath a sloping terrain. <em>P<sub>max<\/sub><\/em> represents the highest injection pressure (step 3) and steps 1, 2, 4, and 5 represent multiples of <em>P<sub>max<\/sub><\/em> as shown in <a href=\"#X5fb289fc2a048d1e1fb7f46b54557e8be5805e1\">Figure 137<\/a> (Qui\u00f1ones\u2011Rozo, 2010).<\/p>\n<\/div>\n<div class=\"bc-figure figure\" data-custom-style=\"Captioned Figure\"><img decoding=\"async\" style=\"display: block; margin-left: auto; margin-right: auto; ;width: 5.83333in; height: 3.06464in;\" src=\"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-content\/uploads\/sites\/40\/2026\/08\/file142-2.jpg\" alt=\"\" \/><\/p>\n<div class=\"bc-figcaption figcaption\">\n<div data-custom-style=\"Image Caption\">\n<div class=\"figcaption-text\">\n<p><span id=\"X5fb289fc2a048d1e1fb7f46b54557e8be5805e1\" class=\"anchor\"><strong>Figure 137 \u2011<\/strong> Five pressure steps used in a Lugeon test. <em>P<sub>max<\/sub><\/em> is the maximum pressure computed as 1 psi per foot of overburden above the test zone (2.26&#215;10<sup>4<\/sup> pascals per meter of overburden above the test zone). After step rates have stabilized, the total flow rate is measured every minute over a 10 min interval and the flow rate is determined by averaging the values (Qui\u00f1ones\u2011Rozo, 2010).<\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>Water pressure and flow rate are recorded during each step of the test using a totalizing flowmeter, pressure gage\/sensor, and timer. A purge valve on the injection system is used to vent excess pressure from the injection pump which controls the injection pressure into the test interval (<a href=\"#X47969367424f124f36c0ff8b629376c1a46d290\">Figure 135<\/a>). After establishing a constant\u2011flow rate, each stage is typically run for 10 minutes. Pressure and totalizing flowmeter readings are recorded each minute, and the total &#8216;take&#8217; (inflow volume) of the test interval is calculated in liters for each step. The average flow rate is computed from the step data. A hydraulic conductivity value is calculated for each step, expressed as an empirical Lugeon value, which is defined as the hydraulic conductivity required to achieve a flow rate of 1 liter per minute per meter of test interval under a reference water pressure equal to 1 MPa.<\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>Lugeon tests are analyzed based on the total injection pressure and flow during a given step. One Lugeon is equivalent to 1.3 x 10<sup>\u20115<\/sup> centimeters per second under homogenous and isotropic conditions (Qui\u00f1ones\u2011Rozo, 2010). Separate Lugeon values are calculated for each step using Equation\u00a0<a href=\"#X0529a98ed096d2b66774b404eedb78843a988f4\">(126)<\/a>.<\/p>\n<\/div>\n<table class=\"gw-eq-table\" style=\"width: 100%;\" data-custom-style=\"Table\">\n<colgroup>\n<col style=\"width: 10%;\" \/>\n<col style=\"width: 75%;\" \/>\n<col style=\"width: 15%;\" \/><\/colgroup>\n<tbody>\n<tr>\n<th><\/th>\n<th style=\"text-align: center;\">[latex]Lugeon\\ Value = \\ \\alpha\\ \\frac{q}{L}\\ \\frac{P_{0}}{P}[\/latex]<\/th>\n<th style=\"text-align: right; white-space: nowrap;\"><span id=\"X0529a98ed096d2b66774b404eedb78843a988f4\" class=\"anchor\">(126)<\/span><\/th>\n<\/tr>\n<\/tbody>\n<\/table>\n<div data-custom-style=\"Body Text\">\n<p>where:<\/p>\n<\/div>\n<table style=\"width: 85%;\" data-custom-style=\"Table\">\n<colgroup>\n<col style=\"width: 14%;\" \/>\n<col style=\"width: 2%;\" \/>\n<col style=\"width: 68%;\" \/> <\/colgroup>\n<thead>\n<tr>\n<th style=\"text-align: right;\"><em>Lugeon<\/em><\/th>\n<th style=\"text-align: left;\">=<\/th>\n<th>reflects hydraulic conductivity of 1.3 x 10<sup>\u20115<\/sup> centimeters per second when determined under homogenous, isotropic conditions<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: right;\"><em>\u03b1<\/em><\/td>\n<td style=\"text-align: left;\">=<\/td>\n<td>dimensionless unit\u2011conversion factor (1 for SI units which would be in liters per minute, meters, and megapascals)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right;\"><em>q<\/em><\/td>\n<td style=\"text-align: left;\">=<\/td>\n<td>average flow rate from a single step (in liters per minute)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right;\"><em>L<\/em><\/td>\n<td style=\"text-align: left;\">=<\/td>\n<td>length of test interval (in meters)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right;\"><em>P<sub>0<\/sub><\/em><\/td>\n<td style=\"text-align: left;\">=<\/td>\n<td>reference pressure, which is defined as 1 megapascal<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right;\"><em>P<\/em><\/td>\n<td style=\"text-align: left;\">=<\/td>\n<td>total pressure head above static pressure (i.e., injection pressure + pressure head + frictional losses)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div data-custom-style=\"Body Text\">\n<p>Houlsby (1976) developed a method to select a representative Lugeon value or equivalent hydraulic conductivity to represent the test interval using the observed patterns of Lugeon values. His method uses a bar graph of Lugeon values calculated for each step. The test values are matched to a pattern, and a method to generate a representative hydraulic conductivity value is selected. The patterns are labeled as representing flow regimes that include (1) laminar flow, (2) turbulent flow, (3) dilation, (4) wash\u2011out, or (5) void filling. Each regime is described in the caption of <a href=\"#X9e3a48cff505f46a8ba070f4ebe2edc3b03da47\">Figure 138<\/a>.<\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p><img decoding=\"async\" style=\"display: block; margin-left: auto; margin-right: auto; ;width: 5.83333in; height: 6.90877in;\" src=\"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-content\/uploads\/sites\/40\/2026\/08\/file143-2.jpg\" alt=\"\" \/><\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<div class=\"figcaption-text\">\n<p><span id=\"X9e3a48cff505f46a8ba070f4ebe2edc3b03da47\" class=\"anchor\"><strong>Figure 138 \u2011\u00a0<\/strong>Lugeon\u2011test patterns and flow\u2011regime interpretation (Houlsby, 1976). The pressure stages are the same for each Lugeon pattern. However, the calculation of a representative hydraulic conductivity value is dependent on the pattern of test Lugeon values. (1) Laminar Flow \u2013 All Lugeon values for each step are similar, therefore laminar flow is occurring. The representative value is the average of all five steps. (2) Turbulent flow \u2013 The lowest Lugeon value occurs at the highest pressure, therefore turbulent flow is occurring. The representative value is the Lugeon value for the highest pressure. (3) Dilation \u2013 The highest Lugeon value occurs at the highest pressure, therefore fracture dilation is occurring at high pressure. The representative value is the average of the low pressure (1,5) or medium pressure (2,4) steps. (4) Wash\u2011Out \u2013 Lugeon values increase with each step regardless of pressure, therefore gouge or weathered minerals are washing out of fractures. The representative Lugeon value is the highest observed value unless special conditions dictate otherwise. (5) Void Filling \u2013 Lugeon Values decrease with each step regardless of pressure, therefore gouge or weathered minerals are filling in small aperture fractures. The representative value is the Lugeon value for the lowest pressure.<\/span><\/p>\n<\/div>\n<\/div>\n<div data-custom-style=\"Block Text\">\n<blockquote><p><strong>Example<\/strong><\/p><\/blockquote>\n<\/div>\n<div data-custom-style=\"First Paragraph\">\n<p>A 11.6\u2011m long test section of borehole in a fractured sandstone is isolated by a straddle\u2011packer system (two packers). The first Lugeon test step is conducted for 10 minutes, has an average total head pressure above static of 0.084 megapascals (MPa) and the formation takes a total of 390 liters throughout the step. Using Equation\u00a0<a href=\"#X0529a98ed096d2b66774b404eedb78843a988f4\">(126)<\/a> with an SI unit conversion factor of one, a total head of 0.084 MPa, and an average flow rate of 39 liters per minute yields 40 Lugeons.<\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<div class=\"display-math\" data-custom-style=\"Display Equation\">\n<p>[latex]Lugeon\\ Value = \\alpha\\ \\frac{q}{L}\\ \\frac{P_{0}}{P} = \\ 1\\ \\frac{39\\frac{L}{\\min}}{11.6\\ m}\\ \\frac{1\\ MPa}{0.084\\ MPa} = 40\\ Lugeons[\/latex]<\/p>\n<\/div>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>A Lugeon value of 40 is approximately 5.2 x 10<sup>\u20114<\/sup> cm\/s. As indicated in the parameter definitions for Equation\u00a0<a href=\"#X0529a98ed096d2b66774b404eedb78843a988f4\">(126)<\/a>, one Lugeon value is equivalent to 1.3 x 10<sup>\u20115<\/sup> centimeters per second under homogenous and isotropic conditions (Qui\u00f1ones\u2011Rozo 2010).<\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>The software program AquiferTest V12 provides methods to interpret Lugeon\u2011test results. The user\u2019s manual provides details on methods and data requirements (Waterloo Hydrogeologic, 2021).<\/p>\n<\/div>\n<\/div>\n<div id=\"drillstem-test\" class=\"level3\">\n<h3>Drill\u2011Stem Test<\/h3>\n<div data-custom-style=\"First Paragraph\">\n<p>Estimates of horizontal hydraulic conductivity using a packed\u2011off interval of a borehole have been of interest to the petroleum industry for many years (e.g., Mathews &amp; Russel, 1967; Earlougher, 1977). The drill\u2011stem test procedure is also applicable to the characterization of some confined hydrogeologic settings.<\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>Conceptually, a drill\u2011stem test involves outfitting the drill stem with a test apparatus within the interval of interest that has packers, valves, and pressure\u2011monitoring systems. The packer system is used to isolate a section of borehole. Valves are opened at the start of the test and fluid from the packer zone flows into the drill stem for a period of time. Then the valve is closed. The pressure system monitors the starting formational pressures and the recovery pressures after the value is closed. A discharge rate is computed from the rate that the volume of water fills the drill stem once the test is initiated. Analyses of the data are achieved by using recovery theory once the valve system is closed. Domenico and Schwartz (1998) have a brief discussion of the method and data analysis. Additional, detail and methods are found on sites like <a href=\"https:\/\/wiki.aapg.org\/Drill_stem_testing\">wiki.aapg.org\/Drill_stem_testing<\/a>\u2197 and in the literature.<\/p>\n<\/div>\n<div data-custom-style=\"Body Text\">\n<p>Section 16 addresses hydraulic testing to characterize low\u2011permeability units such as confining units or aquitards.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"author":8,"menu_order":68,"template":"","meta":{"pb_show_title":"on","pb_short_title":"","pb_subtitle":"","pb_authors":[],"pb_section_license":""},"chapter-type":[],"contributor":[],"license":[],"class_list":["post-1795","chapter","type-chapter","status-publish","hentry"],"part":593,"_links":{"self":[{"href":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-json\/pressbooks\/v2\/chapters\/1795","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-json\/pressbooks\/v2\/chapters"}],"about":[{"href":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-json\/wp\/v2\/types\/chapter"}],"author":[{"embeddable":true,"href":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-json\/wp\/v2\/users\/8"}],"version-history":[{"count":4,"href":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-json\/pressbooks\/v2\/chapters\/1795\/revisions"}],"predecessor-version":[{"id":3565,"href":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-json\/pressbooks\/v2\/chapters\/1795\/revisions\/3565"}],"part":[{"href":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-json\/pressbooks\/v2\/parts\/593"}],"metadata":[{"href":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-json\/pressbooks\/v2\/chapters\/1795\/metadata\/"}],"wp:attachment":[{"href":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-json\/wp\/v2\/media?parent=1795"}],"wp:term":[{"taxonomy":"chapter-type","embeddable":true,"href":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-json\/pressbooks\/v2\/chapter-type?post=1795"},{"taxonomy":"contributor","embeddable":true,"href":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-json\/wp\/v2\/contributor?post=1795"},{"taxonomy":"license","embeddable":true,"href":"https:\/\/books.gw-project.org\/an-introduction-to-hydraulic-testing-in-hydrogeology\/wp-json\/wp\/v2\/license?post=1795"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}